Comparison of human, primate, and canine femora: implications for biomaterials testing in total hip replacement.
نویسندگان
چکیده
The canine model remains an animal of choice for determining the efficacy and safety of various materials and designs used in human total hip replacement (THR). The primate also is used in orthopedic-related research for studying limb anatomy, gait, and age-related bone loss. In order to better understand the appropriateness of these animal models for human THR, external morphologies of thirty-three adult Caucasian human, sixteen adult chimpanzee, and forty-two adult greyhound femora were compared using osteometric methods. Measured parameters included anteversion angle, cervico-diaphyseal angle, femoral head offset in the frontal plane, and anterior bow profiles along the femoral diaphysis. Although some of the measured parameters were approximately similar between species (e.g., mean cervico-diaphyseal angle of humans and chimpanzees), the majority demonstrated morphologic differences that may be biomechanically significant for interpreting stress transfer across the hip (e.g., mean anteversion angle and mean normalized femoral head offset between species). Additionally, age-related changes in proximal femoral morphology and gait pattern, as well as species-related differences in local muscle and inertial forces, may result in notably different loading conditions across the hip joint of each species. Therefore, discretion must be exercised when evaluating canine or primate THR materials and designs for potential use in the human hip.
منابع مشابه
Comparison of human and canine external femoral morphologies in the context of total hip replacement.
The canine is frequently used as a model for human hip arthroplasty research. In order to better understand the appropriateness of the canine as a model for human total hip replacement studies, the external morphology of canine and human femurs were examined and compared. Several differences were found between canine and human femora, including angular measurements, anterior bow, and femoral he...
متن کاملBone density study of the proximal femur after hip arthroplasty with porous-coated implants
Progressive loss of bone mineral density around the femora! component of total hip replacement continues to pose a threat to long term prosthetic survival. A linear study was undertaken to measure bone mineral density on a monthly basis following total hip arthroplasty in 11 male patients. The opposite femur was used as the control measurement. Bone mineral density was unchanged at two mo...
متن کاملThe Odocoileus virginianus Femur: Mechanical Behavior and Morphology
Biomechanical research relies heavily on laboratory evaluation and testing with osseous animal structures. While many femora models are currently in use, including those of the European red deer (Cervus elaphus), the Odocoileus virginianus femur remains undocumented, despite its regional abundance in North America. The objective of this study was to compare biomechanical and morphological prope...
متن کاملAssessing the dog as a model for human total hip replacement. Analysis of 38 canine cemented femoral components retrieved at post-mortem.
Post-mortem retrieval of canine, cemented femoral components was analysed to assess the performance of these implants in the dog as a model for human total hip replacement (THR). Mechanical testing and radiological analysis were performed to determine the stability of the implant and the quality of the cement. Thirty-eight implants from 29 dogs were retrieved after time intervals ranging from 0...
متن کاملBiomechanical evaluation of adjunctive cerclage wire fixation for the prevention of periprosthetic femur fractures using cementless press-fit total hip replacement.
Periprosthetic femoral fractures are a common complication associated with cementless press-fit total hip arthroplasty. The use of prophylactic cerclage wire fixation has been advocated to reduce this complication. The objective of this study was to evaluate whether a double loop cerclage wire, used as adjunctive fixation, increased the peak torsional load to failure in femora implanted with pr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomedical materials research
دوره 40 3 شماره
صفحات -
تاریخ انتشار 1998