Decontaminating infectious laboratory waste by autoclaving.
نویسندگان
چکیده
The temperature profile of infectious laboratory waste being autoclaved was examined relative to the type of containers used in the process. A standardized waste load (1,750 +/- 4 g) placed in the container was evaluated by using a direct readout thermocouple. The sensor of the thermocouple was placed within an unused and outdated agar plate, centrally located about 5 cm from the bottom of the container. The gravity displacement autoclave tested reached 121 degrees C within 3 min. Waste within a steel container (plus 1 liter of water) reached 108, 120, and 122 degrees C at 12, 30, and 50 min, respectively. Without the addition of water, the corresponding temperatures were 60, 110, and 120 degrees C, respectively. With a steel container, "autoclavable" plastic bags, and no additional water, the temperatures were 36, 71, and 105 degrees C, respectively. When 1 liter of water was placed in the autoclavable bag, the temperatures were 98, 115, and 121 degrees C, respectively. Waste within a polypropylene container (dimensions similar to those of the steel container) with and without the addition of 1 liter of water, reached a maximum temperature of 108 degrees C at 50 min. With a polypropylene container, autoclavable plastic bag, and 1 liter of water, the corresponding temperature was 99 degrees C. Without the addition of water, the temperature was 92 degrees C. The importance of container, moisture, and material in autoclaving was demonstrated.
منابع مشابه
Use of containment pans and lids for autoclaving caustic solutions.
As a means of decontaminating instruments possibly exposed to Creutzfeldt-Jakob disease, the World Health Organization has recommended immersion and autoclaving in sodium hydroxide. However, this recommendation has raised concerns of possible damage to autoclaves, and hazards to operators as a result of the caustic vapors. A series of experiments has been conducted that demonstrate that there a...
متن کاملConceptual Design of a Commercial Spent Pot Liner Treatment Plant
All aluminium smelter plants discharges high volume extremely toxic electrolytic cell waste known as spent pot liner. Over the years scientists have improvised various methods for disposing these toxic wastes either by diluting with inert material or recovering its carbon value after decontaminating the toxic waste. Present paper outlines conceptual design of a commercial treatment plant which ...
متن کاملEvaluation of medical waste incinerators in Alexandria.
Medical establishments play important roles in different activities by using of modern technology to serve the humans and the environment through different departments in the establishment and its firms. Medical wastes are considered as a hazardous waste because they contain toxic materials, infectious, or non-infectious wastes and they are considered as a hazard to millions of patients, health...
متن کاملManagement of infectious waste by US hospitals.
In July 1987 and January 1988, forty-six percent (441/955) of randomly selected US hospitals responded to a questionnaire intended to identify their waste disposal practices. Survey responses were received from hospitals in 48 states. United States hospitals generated a median of 6.93 kg of hospital waste per patient per day and infectious waste made up 15% of the total hospital waste. Most hos...
متن کاملبررسی عملکرد دستگاه سترون سازی زباله های عفونی بیمارستان شهید بهشتی کاشان و تعیین شرایط بهینه راهبری آن
Background and Objectives Autoclaving is one of the methods which sterilizes infectious solid wastes. Since variety of parameters such as temperature, time, and pressure influence autoclave performance, this study was carried out to evaluate the parameters and set optimum condition for the autoclave apparatus applied in Shahid Beheshti Hospital in Kashan.Materials and Methods: In this descrip...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied and environmental microbiology
دوره 44 3 شماره
صفحات -
تاریخ انتشار 1982