Evaporative cooling of sodium atoms.
نویسندگان
چکیده
s (to be published) Abstract No. 1-M3. [9] W. Petrich, M. H. Anderson, J. R. Ensher, and E. A. Cornell, in Fourteenth International Conference on Atomic Physics, Boulder Colorado, 1994 (Ref. [8]). [10] M. Kasevich (private communication). [11] E. Tiesinga, A. J. Moerdijk, B. J. Verhaar, and H. T. C. Stoof, Phys. Rev. A 46, R1167 (1992). [12] H. F. Hess, Phys. Rev. B 34, 3476 (1986). [13] K. B. Davis, M.-O. Mewes, and W. Ketterle, Appl. Phys. B 60, 155 (1995). [14] D. E. Pritchard, K. Helmerson, and A. G. Martin, in Proceedings of the 11th International Conference on Atomic Physics, edited by S. Haroche, J. C. Gay, and G. Grynberg (World Scientific, Singapore, 1989), p. 179. [15] M. Drewsen et al., Appl. Phys. B 59, 283 (1994). [16] O. J. Luiten et al., Phys. Rev. Lett. 70, 544 (1993). [17] C. R. Monroe, E. A. Cornell, C. A. Sackett, C. J. Myatt, and C. E. Wieman, Phys. Rev. Lett. 70, 414 (1993). [18] D. W. Snoke and J. P. Wolfe, Phys. Rev. B, 39 39 (1989). [19] A.-J. Moerdijk and B. J. Verhaar (private communication). [20] This does not contradict the observation of d-wave scattering in recent photoassociation experiments at 0.6 mK [L. P. Ratliff et al., J. Chem. Phys. 101, 2638 (1994)]. Since the ratio of dand s-wave partial cross sections scales as T 2 in inelastic scattering, the d-wave contribution to photodissociation at 200 mK should be less than 10%, and even smaller for elastic scattering which requires two passages through the centrifugal barrier. [21] A. J. Moerdijk and B. J. Verhaar, Phys. Rev. Lett. 73, 518 (1994). [22] R. Côté and A. Dalgarno, Phys. Rev. A 50, 4827 (1994). [23] J. M. Doyle et al., Physica (Amsterdam) 194–196B, 13 (1994). [24] W. Ketterle and D. E. Pritchard, Phys. Rev. A 46, 4051
منابع مشابه
Bose-Einstein condensation of ultracold atomic gases
Bose-Einstein condensation in a dilute gas of sodium atoms has been observed. The atoms were trapped in an optically plugged magnetic trap or in a cloverleaf magnetic trap. Rf induced evaporative cooling increased the phase-space density by six orders of magnitude. We summarize the different techniques used, and discuss recent studies of properties of Bose condensates with an outlook on future ...
متن کاملBose-Einstein Condensation in a Tightly Confining dc Magnetic Trap.
Bose-Einstein condensation of sodium atoms has been observed in a novel “cloverleaf” trap. This trap combines tight confinement with excellent optical access, using only dc electromagnets. Evaporative cooling in this trap produced condensates of 5 3 106 atoms, a tenfold improvement over previous results. We measured the condensate fraction and the repulsive mean-field energy, finding agreement ...
متن کاملExergy Analysis of Evaporative Cooling for Optimum Energy Consumption in Diverse Climate Conditions
In this paper, exergy of conditioned air, exergy efficiency, irreversibility, and entropy generation of common models of evaporative cooling have been investigated in five cities of Iran. Direct evaporative cooling (DEC), indirect evaporative cooling (IEC), and two-stage IEC/DEC as the most popular methods of cooling have been modeled. Atmospheric conditions are considered as the dead state of ...
متن کاملSpin-polarizing cold sodium atoms in a strong magnetic field
The efficiency of evaporative cooling, which is used for the creation of a Bose-Einstein condensate, depends strongly on the number of particles at the start of the evaporation. A high efficiency can be reached by filling the magneto-optical trap with a large number of atoms and subsequently transferring these atoms to the magnetic trap as efficiently as possible. In our case for sodium this ef...
متن کاملOptimization and increase production and efficiency of gas turbines GE-F9 using Media evaporative cooler in Fars combined cycle power plant
Gas turbines play an important role in supplying power for the country especially in peak electricity load. The main disadvantages are the turbines, they produce large changes are a result of climate change. However, in times of peak electricity grid and at the same time warm months, can produce gas turbines under the effect of ambient temperature, the amount of reduced considerably. The method...
متن کاملDesign and construction of evaporative local cooling coatings and evaluate their efficiency in improving some perceptual indicators in laboratory conditions
Introduction: One way to reduce the level of heat strain is to use personal evaporative cooling coats. such as the wrist, ankle, head and neck. The purpose of this study is to design, construct, and determine the cooling power of local cooling coatings and evaluate their efficiency in improving perceptual indicators in the laboratory. Materials and Methods: Initially, the design and constructio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physical review letters
دوره 74 26 شماره
صفحات -
تاریخ انتشار 1995