Averaging rotational landmarks during total knee arthroplasty reduces component malrotation caused by femoral asymmetry

نویسندگان

  • Tat Woon Chao
  • Liam Geraghty
  • Pandelis Dimitriou
  • Simon Talbot
چکیده

BACKGROUND Femoral component malrotation is a common cause of patient dissatisfaction after total knee arthroplasty. The sulcus line (SL) is more accurate than Whiteside's line as it corrects for variation in the coronal orientation of the groove. The hypothesis is that averaging the SL and posterior condylar axis (PCA) will reduce femoral malrotation. METHODS The component was inserted at a position between the SL and PCA in 91 patients. An intraoperative photograph was taken showing the landmarks. These were compared to the component position achieved relative to the surgical epicondylar axis (SEA) on a postoperative CT scan. The component position was compared to the position achieved using the individual landmarks. RESULTS Relative to the SEA, the final component position was 0.6° (SD 1.4°, range -3.8° to +4.0°), the coronally corrected SL position was -0.7° (SD 2.3°, -5.5° to +4.6°), the PCA position was 0.9° (SD 1.9°, -6.1° to +5.0°). Averaging the landmarks significantly decreased the variance of the component position compared to using the SL and PCA individually. The number of outliers (>3° from SEA) was also significantly less (p < 0.05) for the average position (2/84) when each was compared to the SL (16/84) and PCA (14/84) individually. In 21/84 (25%) of cases, there was more than 4° of divergence between the SL and PCA. CONCLUSIONS Averaging the SL and the PCA decreases femoral component malrotation. Femora are frequently asymmetrical in the axial plane. Referencing posterior condyles alone to set rotation is likely to cause high rates of patellofemoral malalignment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Malrotation causing patellofemoral complications after total knee arthroplasty.

Thirty patients with isolated patellofemoral complications after total knee arthroplasty were compared with 20 patients with well functioning total knee replacements without patellofemoral complications. The epicondylar axis and tibial tubercle were used as references on computed tomography scans to measure quantitatively rotational alignment of the femoral and tibial components. The group with...

متن کامل

Effect of Rotational Component Alignment on Clinical Outcome 5 to 7 Years After TKA With the Columbus Knee System.

The aim of the study was to examine the effects of rotational component alignment on outcome after total knee arthroplasty (TKA) with a minimum follow-up of 5 years. For this study, 96 patients were available for follow-up at a mean of 5.7 years after TKA. Computed tomography scans were available in 55 patients. Outcome (Oxford Knee Score [KSS], Knee Injury and Osteoarthritis Outcome Score [KOO...

متن کامل

Averaging different alignment axes improves femoral rotational alignment in computer-navigated total knee arthroplasty.

BACKGROUND Computer navigation systems generally establish the rotational alignment axis of the femoral component on the basis of user-defined anatomic landmarks. However, navigation systems can also record knee kinematics and average alignment axes established with multiple techniques. We hypothesized that establishing femoral rotational alignment with the use of kinematic techniques is more a...

متن کامل

Evaluation of Distal Femoral Rotational Alignment with Spiral CT Scan before Total Knee Arthroplasty (A Study in Iranian Population)

    Background: Evaluating the landmarks for rotation of the distal femur is a challenge for orthopedic surgeons. Although the posterior femoral condyle axis is a good landmark for surgeons, the surgical transepicondylar axis may be a better option with the help of preoperative CT scanning. The purpose of this study was to ascertain relationships among the axes’ guiding distal femur rotational ...

متن کامل

Effect of rotational alignment on outcome of total knee arthroplasty

BACKGROUND AND PURPOSE Poor outcomes have been linked to errors in rotational alignment of total knee arthroplasty components. The aims of this study were to determine the correlation between rotational alignment and outcome, to review the success of revision for malrotated total knee arthroplasty, and to determine whether evidence-based guidelines for malrotated total knee arthroplasty can be ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017