Patients with congenital heart disease: how to determine the eligibility for implantation of a subcutaneous implantable defibrillator?
نویسندگان
چکیده
The clinical value of the implantable cardioverter-defibrillator (ICD) in reducing sudden cardiac death has been proved in selected patients with ischaemic or non-ischaemic cardiomyopathy. Since the introduction of the ICD in the 1980s, the technology has evolved from an epicardial to a transvenous approach. Recently, the subcutaneous cardioverter-defibrillator (S-ICD) has been added to the armamentarium of treatment to prevent sudden cardiac death. Although the S-ICD shares with conventional ICDs the key functions of detecting and defibrillating malignant ventricular arrhythmias, it represents a major departure in terms of design and functionality. Being totally subcutaneous, it is devoid of risks associated with transvenous leads; vascular obstruction, systemic infection, insulation breaches and conductor breaks, and risks associated with transvenous lead extraction if required. The S-ICD system delivers non-programmable 80-J biphasic transthoracic shocks and has the capability to provide ventricular bradycardia pacing up to 30 s post-shock at a rate of 50 bpm. The S-ICD cannot provide pacing for bradycardia, cardiac resynchronization therapy or antitachycardia pacing. For arrhythmia detection and discrimination, the S-ICD system utilizes one of the three subcutaneous ECGs recorded between two sensing electrodes or between a sensing electrode and the pulse generator. Inappropriate shock delivery is an important adverse event with all implantable defibrillators. The rate of inappropriate shocks with the S-ICD was 13.1% over 11 months in the study by Weiss et al. and an annual rate of 7% in the EFFORTLESS (Evaluation oF FactORs ImpacTing CLinical Outcome and Cost EffectiveneSS) S-ICD registry, somewhat higher than that has been reported for transvenous ICDs: 11.5% over20 months in the MADIT-II (Multicenter Automatic Defibrillator Implantation Trial) study. The mechanism of inappropriate shocks is different between S-ICD and conventional defibrillators. The rate of inappropriate shocks for supraventricular arrhythmias is low with S-ICD and in the START (subcutaneous vs. transvenous arrhythmia recognition testing) study, a head-to-head comparison between S-ICD and contemporary transvenous ICD systems, demonstrated superiority of S-ICD with regard to specificity for supraventricular arrhythmia discrimination. However, subcutaneous rhythm analysis is confounded by T-wave oversensing, which is the most common cause of inappropriate shocks with this device. In order to avoid inappropriate shocks due to T-wave oversensing, a pre-implant surface ECG screening template is used to identify patients who are likely to have an unsuitable subcutaneous ECG. Who should receive an S-ICD device? Clearly, patients who have a pacing requirement are not eligible. Fortunately, most ICD recipients do not have a pacing indication and can receive either a subcutaneous or transvenous device. Implantation of an ICD in a young person requires careful consideration as to the most suitable device. Young patients are likely to have their device for decades and are at the highest risk of device complications. When considering patients with congenital heart disease (CHD), ICD implantation can be challenging due to congenital venous anomalies, surgical obstacles (patches, conduits, and baffles), and ventricular geometry and position. With contemporary transvenous ICD systems, these patients are exposed to the near certainty of lead failure and the need for lead revision, and the hazards of either multiple intravascular leads or lead extraction. From this perspective, patients with CHD may be a target population for S-ICD placement when they have no pacing indication. Zeb et al. have explored the surface ECG characteristics in three groups of CHD patients (surgically corrected transposition of the
منابع مشابه
Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus
Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...
متن کاملIntrapericardial Implantation of an Implantable Cardioverter-Defibrillator in a Child
Implantable cardioverter defibrillator (ICD) can be a crucial therapeutic modality for pediatric patients with congenital heart disease, Brugada syndrome, long QT syndrome and cardiomyopathy. Because transvenous implantation of ICD is mostly unfeasible for pediatric patients due to anatomical and technical limitations, epicardial patch type or subcutaneous type ICD have been used. Implantation ...
متن کاملRight Parasternal Lead Placement Increases Eligibility for Subcutaneous Implantable Cardioverter Defibrillator Therapy in Adults With Congenital Heart Disease.
BACKGROUND The subcutaneous implantable cardioverter defibrillator (S-ICD) provides an attractive option for patients with congenital heart disease (CHD) in whom a transvenous defibrillator is contraindicated. Given the unusual cardiac anatomy and repolarization strain, the surface electrocardiogram (ECG) is frequently abnormal, potentially increasing the screen failure rate. METHODSANDRESULT...
متن کاملTHE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL
Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...
متن کاملLead Extraction in Congenital Heart Disease Patients – Indications, Technique and Experience
Implantation of pacemakers and implantable cardioverter defibrillators (ICDs) are common procedures associated with very low complication rates(1-3). Device therapy is frequently used in the management of adult congenital heart disease (ACHD) patients given the high prevalence of arrhythmic complications encountered in this population. The ACHD population continues to grow at a rapid pace. It i...
متن کاملClinical Experience With the Subcutaneous Implantable Cardioverter-Defibrillator in Adults With Congenital Heart Disease.
BACKGROUND Sudden cardiac death is a major contributor to mortality for adults with congenital heart disease. The subcutaneous implantable cardioverter-defibrillator (ICD) has emerged as a novel tool for prevention of sudden cardiac death, but clinical performance data for adults with congenital heart disease are limited. METHODS AND RESULTS A retrospective study involving 7 centers over a 5-...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
دوره 17 7 شماره
صفحات -
تاریخ انتشار 2015