The assessment of three methods to verify tracheal tube placement in the emergency setting.

نویسندگان

  • Taku Takeda
  • Koichi Tanigawa
  • Hitoshi Tanaka
  • Yuri Hayashi
  • Eiichi Goto
  • Keiichi Tanaka
چکیده

We studied prospectively the reliability of clinical methods, end-tidal carbon dioxide (ETCO(2)) detection, and the esophageal detector device (EDD) for verifying tracheal intubation in 137 adult patients in the emergency department. Immediately after intubation, the tracheal tube position was tested by the EDD and ETCO(2) monitor, followed by auscultation of the chest. The views obtained at laryngoscopy were classified according to the Cormack grade. Of the 13 esophageal intubations that occurred, one false-positive result occurred in the EDD test and auscultation. In the non-cardiac arrest patients (n=56), auscultation, the ETCO(2), and EDD test correctly identified 89.3, 98.2*, and 94.6%* of tracheal intubations, respectively (*, P<0.05 vs. the cardiac arrest patients). In the cardiac arrest patients (n=81), auscultation, the ETCO(2), and the EDD tests correctly identified 92.6**, 67.9, and 75.3% of tracheal intubations, respectively (**, P<0.05 vs. EDD and ETCO(2)). The frequencies of Cormack grade 1 or 2 were 83.9% in the non-cardiac arrest, and 95.1% in the cardiac arrest patients. In conclusion, the ETCO(2) monitor is the most reliable method for verifying tracheal intubation in non-cardiac arrest patients. During cardiac arrest and cardiopulmonary resuscitation, however, negative results by the ETCO(2) or the EDD are not uncommon, and clinical methods are superior to the use of these devices.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nasopharyngeal tube placement in emergency intubated patients with decreased consciousness with a new guidewire: a prospective randomized controlled trial

Background: There is some demand for nasogastric tube insertion in unconscious or ICU patients. Nasogastric tubes are generally made of flexible plastic materials, prone to twisting and deviation by the tracheal tube, when passing through the pharynx and esophageal opening, making it difficult to insert the NG-tube properly. We hypothesized that NG-tube insertion with help of guidewire can sign...

متن کامل

Prehospital determination of tracheal tube placement in severe head injury.

OBJECTIVES The aim of this prospective study in the prehospital setting was to compare three different methods for immediate confirmation of tube placement into the trachea in patients with severe head injury: auscultation, capnometry, and capnography. METHODS All adult patients (>18 years) with severe head injury, maxillofacial injury with need of protection of airway, or polytrauma were int...

متن کامل

Tracheal T-Tube Stent for Laryngotracheal Stenosis: Ten Year Experience

Introduction: The purpose of this retrospective study was to evaluate the outcome following stenting over a period of 10 years in patients with chronic laryngotracheal stenosis.   Materials and Methods: Between 2000–2010, out of 111 patients with laryngotracheal trauma, 71 underwent tracheal        T-stenting for laryngotracheal stenosis in the Department of Otorhinolaryngology at the Governmen...

متن کامل

Predictive Value of Tracheal Rapid Ultrasound Exam Performed in the Emergency Department for Verification of Tracheal Intubation

BACKGROUND Verification of the correct placement of the endotracheal tube (ETT) has been one of the most challenging issues of airway management in the field of emergency medicine. Early detection of oesophagal intubation through a reliable method is important for emergency physicians. AIM The aim of this study was to assess the diagnostic accuracy of tracheal rapid ultrasound exam (TRUE) to ...

متن کامل

Extubation Failure in an Adolescent Patient after General Anesthesia for Gastrostomy Tube Placement

Myasthenia gravis (MG) is an autoimmune disease resulting in destruction of the post-synaptic nicotinic receptors at the neuromuscular junction. Classically, the earliest symptoms of MG are ocular, including ptosis and diplopia. Other less common early symptoms include dysphagia and fatigable chewing. Our case report describes the unusual presentation of MG in a teenager patient and presented f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Resuscitation

دوره 56 2  شماره 

صفحات  -

تاریخ انتشار 2003