Early membrane damage during coronary reperfusion in dogs. Detection by radiolabeled anticardiac myosin (Fab')2.

نویسندگان

  • L H Frame
  • J A Lopez
  • B A Khaw
  • J T Fallon
  • E Haber
  • W J Powell
چکیده

There is currently great interest in acute coronary reperfusion as a therapeutic modality for severe myocardial ischemia. While some studies have demonstrated a reduction in the overall extent of necrosis by early reperfusion, other studies have identified potentially deleterious effects produced by reflow. Because membrane disruption may be an important mechanism of irreversible cell injury, we measured changes in cell membrane integrity early during reperfusion using radiolabeled anticardiac myosin (Fab')2 antibody fragments in dogs. Our method involved brief periods of exposure to the (Fab')2 so that the levels of (Fab')2 binding indicated the degree of membrane disruption at discrete times during the progression of cell injury. In the first protocol (Fab')2 fragments labeled with either 125I and 131I were injected into the left circumflex coronary artery at the onset of reflow and at 45 min of reflow after a 1-h circumflex artery occlusion. Coronary sinus flow was diverted for 5 min following each injection to prevent recirculation. The (Fab')2 binding ratio (ischemic/control) increased during the first 45 min of reflow in each of eight experiments (mean increase 170%, P less than 0.01). No significant increase in (Fab')2 binding was observed in five additional experiments in which nonspecific (Fab')2 was injected. This indicates that the increase in binding seen with antimyosin-specific (Fab')2 was due to changes in specific binding rather than to alterations in (Fab')2 delivery produced by changes in blood flow distribution. The increase in membrane damage during reflow was confirmed by a second protocol in which each animal received only a single left atrial injection of (Fab')2 followed by rapid excision of the heart. The (Fab')2 binding ratio was 1.7 +/- 0.3 (SEM) in the group that received (Fab')2 at the onset of reflow and 3.7 +/- 0.6 (SEM) (P less than 0.05) in the group that received (Fab')2 after 45 min of reflow. In a third set of experiments in which hyperosmotic mannitol was infused during reflow the mean increase in (Fab')2 binding using the first protocol was only 80 +/- 40 vs. 170 +/- 30% without mannitol (P less than 0.05). Thus, membrane damage develops early during coronary reperfusion following 1 h of circumflex coronary artery occlusion, and part of this membrane damage can be prevented by altering the conditions of reflow. A method involving brief exposure of the myocardium to antimyosin (Fab')2 is promising for detecting changes in membrane integrity during evolving ischemic injury.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Localization of cardiac myosin-specific antibody in myocardial infarction.

Specific localization of purified antibody against cardiac myosin has been demonstrated in areas of altered myocardial membrane permeability after experimental myocardial infarction. Intravenously administered radioiodine-labeled antimyosin was selectively localized in infarcted myocardium of seven dogs 24 h after coronary occlusion. The mean ratio (+/-SE) of antimyosin antibody in infarcted to...

متن کامل

Experimental myocardial infarct imaging following intravenous administration of iodine-131 labeled antibody (Fab')2 fragments specific for cardiac myosin.

Canine myocardial infarcts resulting from ligation of the left anterior descending coronary artery were localized in vivo by gamma scintigraphy following the intravenous injection of l'I anticardiac myosin antibody (Fab')2. The anteroapical location of the image was confirmed by demonstration of the blood pool with "mTc sulfur colloid, and by subsequent imaging of the excised heart. The scintig...

متن کامل

99mTc-sestamibi uptake and retention during myocardial ischemia and reperfusion.

BACKGROUND 99mTc-methoxyisobutyl isonitrile (Sestamibi) is a new perfusion agent that has shown promise for the noninvasive detection of myocardial salvage after coronary reperfusion in acute myocardial infarction. The objective of this study was to further validate that myocardial uptake and retention of Sestamibi after reperfusion in a canine myocardial infarction model are markers of tissue ...

متن کامل

Localization of radiolabeled cardiac myosin-specific antibody in myocardial infarcts. Comparison with technetium-99m stannous pyrophosphate.

The myocardial uptake of radioiodinated (Fab')2 fragments of antimyosin antibody [125I-(Fab')2] was compared with simultaneously administered 99mTc-pyrophosphate (Tc-PYP) in dogs undergoing coronary occlusion for 24 (N=6) or 72 hours (N=5). Relative concentrations of both agents in normal and infarcted myocardium were related to regional blood flow as determined by distribution of 55Sr-labeled ...

متن کامل

Detection of serum cardiac myosin light chains in acute experimental myocardial infarction: radioimmunoassay of cardiac myosin light chains.

To develop a more specific plasma test for myocardial infarction, antibodies specific for cardiac myosin light chains (CM-LC) were elicited that showed less than 3% cross-reactivity with skeletal muscle light chains. These antibodies were used to develop a radioimmunoassay for CM-LC that had a sensitivity of 20 ng (+/- 4 SD; P less than 0.001). Normal dog plasma showed no measurable concentrati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of clinical investigation

دوره 72 2  شماره 

صفحات  -

تاریخ انتشار 1983