Effects of anatomical changes on pencil beam scanning proton plans in locally advanced NSCLC patients.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Daily anatomical variations can cause considerable differences between delivered and planned dose. This study simulates and evaluates these effects in spot-scanning proton therapy for lung cancer patients. MATERIALS AND METHODS Robust intensity modulated treatment plans were designed on the mid-position CT scan for sixteen locally advanced lung cancer patients. To estimate dosimetric uncertainty, deformable registration was performed on their daily CBCTs to generate 4DCT equivalent scans for each fraction and to map recomputed dose to a common frame. RESULTS Without adaptive planning, eight patients had an undercoverage of the targets of more than 2GyE (maximum of 14.1GyE) on the recalculated treatment dose from the daily anatomy variations including respiration. In organs at risk, a maximum increase of 4.7GyE in the D1 was found in the mediastinal structures. The effect of respiratory motion alone is smaller: 1.4GyE undercoverage for targets and less than 1GyE for organs at risk. CONCLUSIONS Daily anatomical variations over the course of treatment can cause considerable dose differences in the robust planned dose distribution. An advanced planning strategy including knowledge of anatomical uncertainties would be recommended to improve plan robustness against interfractional variations. For large anatomical changes, adaptive therapy is mandatory.
منابع مشابه
Proton Beam Therapy for Non-Small Cell Lung Cancer: Current Clinical Evidence and Future Directions
Lung cancer is the leading cancer cause of death in the United States. Radiotherapy is an essential component of the definitive treatment of early-stage and locally-advanced lung cancer, and the palliative treatment of metastatic lung cancer. Proton beam therapy (PBT), through its characteristic Bragg peak, has the potential to decrease the toxicity of radiotherapy, and, subsequently improve th...
متن کاملA Review of Proton Radiation Therapy and the Path to Widespread Clinical Adoption
After many years of development, proton therapy is finally reaching the point of mass adoption in clinical practice. Advances in particle accelerator technology and improved dose delivery techniques have provided strong driving forces for expanded use. Pencil beam scanning (PBS) is the generic name for radiation dose delivery to a target volume using individually controlled small pencil beams o...
متن کاملEffects of Defining Realistic Compositions of the Ocular Melanoma on Proton Therapy
Background: Recent studies in eye plaque brachytherapy have shown a considerable difference between the dosimetric results using water phantom and a model of human eye containing realistic materials. In spite of this fact, there is a lack of simulation studies based on such a model in proton therapy literatures. In the presented work, the effect of utilizing an eye model with ocular media on pr...
متن کاملImpact of robust treatment planning on single- and multi-field optimized plans for proton beam therapy of unilateral head and neck target volumes
BACKGROUND Proton beam therapy is promising for the treatment of head and neck cancer (HNC), but it is sensitive to uncertainties in patient positioning and particle range. Studies have shown that the planning target volume (PTV) concept may not be sufficient to ensure robustness of the target coverage. A few planning studies have considered irradiation of unilateral HNC targets with protons, b...
متن کاملA comparison of the dose distributions from three proton treatment planning systems in the planning of meningioma patients with single‐field uniform dose pencil beam scanning
With the number of new proton centers increasing rapidly, there is a need for an assessment of the available proton treatment planning systems (TPSs). This study compares the dose distributions of complex meningioma plans produced by three proton TPSs: Eclipse, Pinnacle3, and XiO. All three systems were commissioned with the same beam data and, as best as possible, matched configuration setting...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology
دوره 120 2 شماره
صفحات -
تاریخ انتشار 2016