The Diagnosis of Sleep Apnea Typically In- Volves an Overnight Polysomnogram with Continuous Monitoring of Several Physi-
نویسندگان
چکیده
1521 THE DIAGNOSIS OF SLEEP APNEA TYPICALLY INVOLVES AN OVERNIGHT POLYSOMNOGRAM WITH CONTINUOUS MONITORING OF SEVERAL PHYSIOLOGIC parameters and surrogate measures of airflow (nasal pressure [Pn], oronasal thermistor, expired CO2 waveform [PECO2]) using contact sensors. 1-5 A subject can come in contact with at least 20 such sensors during a study. These sensors and the wires can influence not only the usual sleep architecture, but also the posture of the patient during the study night.6-8 Contact sensors like nasal prongs and oronasal thermistors are routinely used as surrogate measures of airflow because they are less obtrusive than the reference-standard airflow sensor, namely, the pneumotachometer.1,9,10 However, the presence of the surrogate airflow sensors and the associated wires in the proximity of the subject’s oronasal area can still cause discomfort to the patient during sleep. Contact sensors also have the potential to misalign during the study, requiring repositioning at the bedside by a technician, to obtain good-quality data. We have demonstrated that measurement of breathing rates is feasible at a distance using thermal infrared imaging (TIRI).11 The method is based on second-order statistics of the presence or absence of the hot expiratory plume in the vicinity of the nostrils. We have also studied a more advanced method that is based on wavelet analysis of the thermal imaging signal on the nostrils themselves.12,13 When analyzing the thermal imaging signal, we extracted the full breathing waveform (rate and amplitude). Consistent segmentation of the nostril area and facial tissue-tracking algorithms14 enabled sustained monitoring of breathing, resulting in functionality equivalent to that of a thermistor, delivered in a contact-free manner. In 5-minute recordings of 20 awake healthy individuals, agreement between breathing waveforms from the virtual (imaging) and contact thermistors was found to be greater than 90%. The hardware and software system that was developed to implement the latest method is called automatic thermal monitoring system (ATHEMOS). The centerpiece of the system is a midwave infrared camera (FLIR® SC-6000), supported by a black body for calibration and a pan-tilt mechanism for positioning. The system is controlled and the acquired imaging signals are processed by real-time custom software developed in our labs. ATHEMOS and the imaging method that we reported on in a previous publication12 constitute the TIRI portion of the present study. The objective in this current study was to determine the efficacy of TIRI to detect apnea and hypopnea by using conventional surrogate airflow sensors as comparison standards during polysomnography. Thus, our hypothesis was that there would be a very high degree of chance-corrected agreement (κ ≥ 0.6) between TIRI and each of the conventional flow Thermal Infrared ImagIng for aIr flow durIng PSg
منابع مشابه
Negative Polysomnogram ifl Patients with Obstructive Sleep Apnea Syndrorne*
We evaluated the possibility that in some patients with obstructive sleep apnea, the initial polysomnogram may be negative. We reviewed polysomnograms performed at the Medical College of Georgia from 1984 to 1990 and found nine patients whose initial polysomnogram was negative but whose repeat polysomnogram confirmed obstructive sleep apnea. All nine patients (five women and four men; average a...
متن کاملA comparison of polysomnography and the WatchPAT in the diagnosis of obstructive sleep apnea.
OBJECTIVE Our goal was to validate the WatchPAT in the diagnosis of obstructive sleep apnea. STUDY DESIGN We conducted a prospective, blinded, nonrandomized clinical trial. METHODS Patients with suspected obstructive sleep apnea scheduled for an overnight level I polysomnogram were offered enrollment in a study to compare the WatchPAT (Itamar Ltd, Israel) device with polysomnography. Patien...
متن کاملEfficacy of daytime continuous positive airway pressure titration in severe obstructive sleep apnoea.
The aim of this study was to evaluate manual nasal continuous positive airway pressure (nCPAP) titration during daytime polysomnography compared with conventional overnight titration for patients with severe obstructive sleep apnoea. Thirty-two patients who underwent daytime titration were retrospectively matched (for age, sex, body mass index and apnoea/hypopnoea index (AHI)) to a group titrat...
متن کاملPortable-monitor testing: an alternative strategy for managing patients with obstructive sleep apnea.
Portable-monitor testing is being used increasingly in ambulatory management pathways for the diagnosis and treatment of patients with obstructive sleep apnea. Wide varieties of portable monitors are commercially available and they range from single-channel recorders to units that record a full polysomnogram. Recent comparative effectiveness research studies have shown that clinical outcomes of...
متن کاملDaytime polysomnogram diagnosis of sleep disorders.
The daytime polysomnogram was used to evaluate 310 consecutive patients with suspected sleep disorders, referred mainly because of excessive daytime sleepiness. Abnormalities consistent with pathologic sleep apnoea were present in 102 cases, and with narcolepsy-cataplexy in 49 cases. The daytime polysomnogram is a readily accessible, accurate, and cost-effective method for diagnosing many sleep...