Systolic pressure variation as diagnostic method for hypovolemia during anesthesia for cardiac surgery.

نویسندگان

  • Ricardo Vieira Carlos
  • Cristina Salvadori Bittar
  • Marcel Rezende Lopes
  • José Otávio Costa Auler Júnior
چکیده

BACKGROUND AND OBJECTIVES An accurate predictor of effective intravascular volume is of paramount importance for patients submitted to major surgical procedures. A new method to evaluate intravascular volume based on systolic blood pressure variations (SPV), (difference between the maximum and minimum systolic values during controlled respiratory cycle) and its variable delta down (dDown) has shown to be a sensitive indicator of ventricular preload. As SPV is not routinely used in clinical practice our purpose was to evaluate the accuracy of this parameter in evaluating volume status of patients submitted to cardiac surgery. METHODS As from specially developed software, blood pressure variation was transmitted in real time from operating room monitor to a network-connected computer. After the adaptation of this system, nine patients submitted to cardiac surgery were evaluated. Variables were recorded in two moments: T0 (before volume replacement) and TP (after volume replacement). At the same time, conventional hemodynamic parameters were also studied and compared to systolic pressure variation. RESULTS Primary study results have shown that SPV (systolic pressure variation), in its dDown component, presents the best variation consistency after volume replacement with starch. Remaining hemodynamic parameters evaluated, although pointing to clear cardiovascular improvement after replacement, are highly variable among the patients and even on expander's response. CONCLUSIONS Results have shown that SPV is a sensitive method to evaluate intravascular volume status in patients under mechanical ventilation, when correlated to central venous pressure, pulmonary capillary wedge pressure and systolic index variations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Arterial and plethysmographic waveform analysis in anesthetized patients with hypovolemia.

BACKGROUND Respiratory-induced arterial and plethysmographic (pulse oximetry) waveform changes were shown to be good predictors of cardiac output response to increased preload. The aim of this study was to evaluate the reliability of arterial and plethysmographic waveform variables in patients with mild hypovolemia. METHODS Patients undergoing autologous hemodilution were studied. After anest...

متن کامل

بررسی هم‌خوانی پارامترهای قلبی با سطوح بیهوشی

Backgraound: It is recommended to use BIS (BISpectral) to determine anesthesia levels. Currently, due to low capacity in Iran, anesthesiologists use cardiac indices, such as pulse rates and blood pressure to detect anesthesia levels. This study was designed to assess association of cardiac parameters with anesthesia levels measured by brain function. Methods: In this descriptive study, 14 pati...

متن کامل

ثبات همودینامیک با کدام رژیم هوشبری در جراحی پیوند رگ‌های کرونر قلب بیماران تحت درمان با بتا-بلوکر بیشتراست؟سوفنتانیل سیس - آتراکوریوم یا سوفنتانیل-پانکرونیوم

    Background and Aim: Hemodynamic stability during anesthesia and operation is the most important aim of anesthesiologists. Every anesthetic drug has its own hemodynamic effects. The interaction of these drugs with each other and with preoperative drugs of the patients, may cause critical changes in patient's hemodynamic status. For a perfect anesthesia induction, while using high doses of op...

متن کامل

A technique for the determination of systolic pressure variation in the systemic and pulmonary arterial circulations.

INTRODUCTION Systolic pressure variation has previously been used to detect the presence of hypovolemia in mechanically ventilated patients but remains difficult to measure. METHODS We describe the application of a commercially available physiological data acquisition system, PowerLab (ADI Instruments Castle Hill, NSW, Australia), to acquire and graphically display simultaneous recordings of ...

متن کامل

A pilot study of the effect of altering airway pressure on systolic pulse pressure variation in the systemic and pulmonary arterial circulations.

OBJECTIVE Systolic pressure variation results from cyclical fluctuation in the intra-thoracic pressure associated with mechanical ventilation and has been used as a measure of relative hypovolemia in mechanically ventilated patients. The impact of the magnitude of the tidal volume and airway pressure on systolic pressure variation, however, has not been examined in mechanically ventilated patie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista brasileira de anestesiologia

دوره 55 1  شماره 

صفحات  -

تاریخ انتشار 2005