Viscoelastic properties of the human medial collateral ligament under longitudinal, transverse and shear loading.

نویسندگان

  • Carlos Bonifasi-Lista
  • Spencer P Lake
  • Michael S Small
  • Jeffrey A Weiss
چکیده

Ligament viscoelasticity controls viscous dissipation of energy and thus the potential for injury or catastrophic failure. Viscoelasticity under different loading conditions is likely related to the organization and anisotropy of the tissue. The objective of this study was to quantify the strain- and frequency-dependent viscoelastic behavior of the human medial collateral ligament (MCL) in tension along its longitudinal and transverse directions, and under shear along the fiber direction. The overall hypothesis was that human MCL would exhibit direction-dependent viscoelastic behavior, reflecting the composite structural organization of the tissue. Incremental stress relaxation testing was performed, followed by the application of small sinusoidal strain oscillations at three different equilibrium strain levels. The peak and equilibrium stress-strain curves for the longitudinal, transverse and shear tests demonstrate that the instantaneous and long-time stress-strain response of the tissue differs significantly between loading conditions of along-fiber stretch, cross-fiber stretch and along-fiber shear. The reduced relaxation curves demonstrated at least two relaxation times for all three test modes. Relaxation resulted in stresses that were 60-80% of the initial stress after 1000 s. Incremental stress relaxation proceeded faster at the lowest strain level for all three test configurations. Dynamic stiffness varied greatly with test mode and equilibrium strain level, and showed a modest but significant increase with frequency of applied strain oscillations for longitudinal and shear tests. Phase angle was unaffected by strain level (with exception of lowest strain level for longitudinal samples) but showed a significant increase with increasing strain oscillation frequency. There was no effect of test type on the phase angle. The increase in phase and thus energy dissipation at higher frequencies may protect the tissue from injury at faster loading rates. Results suggest that the long-time relaxation behavior and the short-time dynamic energy dissipation of ligament may be governed by different viscoelastic mechanisms, yet these mechanisms may affect tissue viscoelasticity similarly under different loading configurations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multiaxial Viscoelastic Properties of Human Medial Collateral Ligament

Ligament viscoelasticity is an important determinant of tissue response to loading, and viscous dissipation modulates the potential for ligament damage or catastrophic failure. The nature of ligament viscoelastic response represents a combined measure of solid phase viscoelasticity and fluid movement. Both of these contributors are likely direction-dependent due to ligament anisotropy. Small si...

متن کامل

Effect of dermatan sulfate glycosaminoglycans on the quasi-static material properties of the human medial collateral ligament.

The glycosaminoglycan of decorin, dermatan sulfate (DS), has been suggested to contribute to the mechanical properties of soft connective tissues such as ligaments and tendons. This study investigated the mechanical function of DS in human medial collateral ligaments (MCL) using nondestructive shear and tensile material tests performed before and after targeted removal of DS with chondroitinase...

متن کامل

Bi-directional mechanical properties of the human forearm interosseous ligament.

Interest in reconstruction of the interosseous ligament (IOL) of the forearm in the setting of longitudinal radio-ulnar dissociation has increased in recent years with hopes of improving clinical outcomes. This increased interest has been accompanied by research on biomechanics of the IOL. However, little is known about stress and strain in the IOL under externally applied forearm loads. This i...

متن کامل

Effect of Low-Power Helium-Neon Laser Irradiation on Collagen Fibril Thickness of Incisized Medial Collateral Ligament of Knee in Rat

Purpose: The aim of the present study is to investigate the effect of low-power Helium-Neon laser (LPL) on collagen fibril thickness of incisized medial collateral ligament of knee joint (MCL) in rat. Materials and Methods: MCL of right hind limb of 35 male adult sprague Dawley rat under general anesthesia were transversly incisized. Rats were randomly divitded into normal, control, first lase...

متن کامل

Influence of Sulfated Glycosaminoglycans on the Transverse Permeability of Porcine Medial Collateral Ligament

INTRODUCTION: Glycosaminoglycans (GAGs) contribute to the hydration of articular cartilage, ligament, and tendon through osmotic and electrostatic interactions with polar water molecules [1]. This mechanism is a strong determinant of perceived viscoelastic behavior of some biological soft tissues under deformation [2-4]. The apparent permeability describes the freedom of fluid to flow through a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic research : official publication of the Orthopaedic Research Society

دوره 23 1  شماره 

صفحات  -

تاریخ انتشار 2005