Automated assessment of polyethylene wear in cemented acetabular components using anteroposterior radiographs of total hip replacements

نویسندگان

  • C. Stuart Kerrigan
  • Stephen J. McKenna
  • Ian W. Ricketts
  • Carlos A. Wigderowitz
چکیده

Polyethylene wear in the acetabular components of hip prostheses is implicated in loosening and failure. Radiographic measurement of wear is used to identify patients at risk and to assess prosthesis designs. This paper focuses on analysis of prostheses with cemented acetabular cups from anteroposterior (AP) radiographs. The articular surface of the femoral head and the acetabular rim marker are modelled as spherical and circular respectively, resulting in elliptical image projections. Methods for automatically localising these structures in radiographs are presented using robust ellipse fitting and various error functions. Special attention is paid to the acetabular marker since this often projects as a highly eccentric ellipse. Robust fitting enables successful localisation in the presence of clutter without the need for user interaction. Finally, the use of these ellipses as reference structures for wear estimation is investigated and the effect of eccentricity errors is highlighted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated Assessment of Acetabular Wear From Anteroposterior Radiographs using Active Ellipses

Acetabular wear is the major cause of aseptic loosening of total hip replacements, leading to costly revision surgery and patient discomfort. To measure acetabular wear from radiographs manually is a labour-intensive task and most of the current computerised methods either do little to alleviate this problem or require costly equipment that prevents use in standard clinical practice. The develo...

متن کامل

Anatomic Anteversion of the Acetabular Component Correlates with Polyethylene Linear Wear in Total Hip Arthroplasty: The Three-Dimensional Numerical Analysis

Background: Although abduction of the acetabular component is considered to predict factors for polyethylene wear attributable to osteolysis, other radiographic factors have yet to be elucidated. The purpose of the present study was to evaluate whether anteversion or change in implantation angle of the acetabular component influences polyethylene linear wear by using standing and supine radiogr...

متن کامل

Validation of a computer-assisted method for measurement of radiographic wear in total hip arthroplasty using all polyethylene cemented acetabular components.

Although cemented all polyethylene (PE) cups have been routinely used in total hip arthroplasty for decades, no computer-assisted method for measurement of radiographic wear has ever been specifically validated for these implants. Using a validated hip phantom model, AP plain hip radiographs were obtained consecutively for eight simulated wear positions. A version of Martell's Hip Analysis Suit...

متن کامل

Polyethylene wear in cemented metal-backed acetabular cups.

We examined radiographic polyethylene wear in 233 cemented total hip arthroplasties (201 patients) with either a metal-backed or a non-metal-backed acetabular cup. All patients had identical cemented one-piece titanium femoral stems with a femoral head diameter of 28 mm. The mean linear wear rate was 0.11 mm/yr in metal-backed sockets and 0.08 mm/yr in non-metal-backed sockets (p = 0.0002). The...

متن کامل

Polyethylene wear in total hip arthroplasty.

Polyethylene wear increasingly has been blamed for osteolysis and granuloma formation after total joint arthroplasty. The authors evaluated the wear difference between bearing surfaces of stainless steel, cobalt chrome, and titanium alloy. They also compared cemented all-polyethylene molded cups with cemented metal-backed molded acetabular cups. These were compared with molded and machined poly...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society

دوره 32 3  شماره 

صفحات  -

تاریخ انتشار 2008