Determination of phytic acid in urine by inductively coupled plasma mass spectrometry.

نویسندگان

  • Jose A Muñoz
  • Manuel Valiente
چکیده

An ICPMS method for the determination of phytic acid in human urine based on the total phosphorus measurement of purified extracts of phytic acid is described. Pretreatment of the sample is required to avoid interference in the ICPMS detection from other phosphorus compounds accompanying phytic acid in urine such as phosphate or pyrophosphate. This treatment consists of a simple filtration of the urine sample followed by complete separation of phytic acid from the mentioned phosphorus components using an anion-exchange solid-phase extraction. Separation/recovery conditions, optimized for standards of phytic acid prepared in water and artificial urine, were successfully applied to natural urine samples, resulting in adequate accuracy and precision. Linear range (0.02-0.6 mg of phytic acid L(-)(1)) and limit of detection (5 microg L(-)(1) phytic acid) are adequate for analysis of the usual amounts of phytic acid present in urine. Phosphate, pyrophosphate, and pH of urine samples at concentrations exceeding their normal physiological ranges do not affect the determination of phytic acid. Because of the simplicity, low sample requirement, and relatively high sample throughput (10 to 6 min per sample for runs between 50 and 100 samples, respectively), the present method presents the best alternative to current methods for phytic acid determination in urine. Results also show that the method is adequate for the differentiation of levels of phytic acid excretion from patients suffering from oxalocalcic urolithiasis and healthy controls, suggesting that low phytic acid concentrations in urine lead to elevated risk of oxalocalcic urolithiasis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of 137Ba Isotope Abundances in Water Samples by Inductively Coupled Plasma-optical Emission Spectrometry Combined with Least-squares Support Vector Machine Regression

A simple and rapid method for the determination of 137Ba isotope abundances in water samples by inductively coupled plasma-optical emission spectrometry (ICP-OES) coupled with least-squares support vector machine regression (LS-SVM) is reported. By evaluation of emission lines of barium, it was found that the emission line at 493.408 nm provides the best results for the determination...

متن کامل

Selective Separation and Preconcentration of trace Amounts of Gallium in Water and Rice Samples using Cloud Point Extraction and Determination by Inductively Coupled Plasma-Atomic Emission Spectrometry

In the present study a cloud-point extraction process using non-ionic surfactant Triton X-114 for selective extraction of gallium from aqueous solutions was developed. The method is based on the complex formation of Ga (III) with N, N′ -bis (salycilidene)-1, 2-phenylenediamine (salophen) as a chelating agent in buffer media of pH 5. After phase separation and dilution of the surfactant-rich pha...

متن کامل

Microwave assisted digestion coupled with inductively coupled plasma optical emission spectrometry for determining element concentrations in halophytes

Introduction: This study was carried out to determine elements (Li, Na, K, Mg, Ca, Ba, B, Al, Si, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Se, Ag and P) in the Suaeda vermiculata (S. vermiculata) and Suaeda aegyptiaca (S. aegyptiaca) in three different regions of Southern Iran using inductively coupled plasma optical emission spectrometry (ICP-OES) after microwave-assisted acid digestion. Materials and ...

متن کامل

Determination of mercury in whole blood and urine by inductively coupled plasma mass spectrometry.

The conventional method for the determination of mercury in clinical samples is cold vapor atomic absorption spectrometry. Sample digestion or pretreatment require large sample volume and long sample preparation time. The inductively coupled plasma mass spectrometry (ICP-MS) method developed in this study requires only 100 microL of sample with practically no preparation, except for dilution wi...

متن کامل

Determination of cadmium and lead in urine by electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry.

Electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry (ETV-ID-ICP-MS) was applied to the determination of Cd and Pb in urine samples. The isotope ratios for each element in each analytical run were calculated from the peak areas of each isotope. A relatively low vaporization temperature was used, which separated the analyte from the major matrix components an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 75 22  شماره 

صفحات  -

تاریخ انتشار 2003