Influence of the descending thoracic aortic cross clamping on bispectral index value and plasma propofol concentration in humans.
نویسندگان
چکیده
BACKGROUND In this study, the authors investigated changes in Bispectral Index (BIS) values and plasma propofol concentrations (Cp) after aortic cross clamping in the descending thoracic aortic aneurysm repair surgery during propofol anesthesia. METHODS Prospectively, in 10 patients undergoing thoracic aortic surgery during total intravenous anesthesia with propofol, BIS values were recorded during cross clamping of the descending thoracic aorta. In this study, the rate of propofol infusion was controlled to keep the BIS value between 30 and 60 throughout surgery. Simultaneously, Cp values in the blood samples taken from the right radial artery (area proximal to cross clamping) and the left femoral artery (area distal to cross clamping) were measured. RESULTS Approximately 15 min after initiating aortic cross clamping, BIS values in all cases started to decrease abruptly. Cp values of samples taken from the radial artery after cross clamping of the aorta were significantly (P < 0.05) increased compared with pre-cross clamp values (1.8 +/- 0.4 microg/ml), and the mean Cp after aortic cross clamping varied between 3.0 and 5.3 microg/ml. In addition, there were significant differences in the Cp values between radial arterial and femoral arterial blood samples throughout aortic cross clamping. Cp values in samples from the radial artery were approximately two to seven times higher than those from the femoral artery. CONCLUSIONS This study showed that Cp values increased and BIS values decreased rapidly after aortic cross clamping in thoracic aortic aneurysm repair surgery during propofol anesthesia. These findings suggested that all anesthesiologists should control the infusion rate carefully, taking the abrupt changes in its pharmacokinetics into consideration, especially during cross clamping of the descending thoracic aorta.
منابع مشابه
Bispectral index decreased to "0" in propofol anesthesia after a cross-clamping of descending thoracic aorta.
THE Bispectral Index (BIS) monitor (BIS® monitor; Aspect Medical System, Inc., Newton, MA) integrates electroencephalographic data via a proprietary algorithm based on empirical data into a nominal 100 to 0 scale, in which 100 represents the awake state and 0 represents the isoelectric electroencephalogram. The BIS® monitor is highly capable of correctly predicting both the loss and recovery of...
متن کاملCross-clamping of the descending thoracic aorta leads to the asymmetrical distribution of propofol during cardiopulmonary bypass surgery
BACKGROUND We hypothesized that cross-clamping of the descending thoracic aorta (CcDTA) would result in significant changes in plasma propofol concentrations (Cp) proximal and distal to the cross-clamp. We investigated the effect of CcDTA on Cp centrally and distally, including the pulmonary artery and the cardiopulmonary bypass (CPB) cannula. METHODS The bispectral index (BIS) was recorded d...
متن کاملFalsely increased bispectral index score during deep hypothermic circulatory arrest in cardiac surgery
Corresponding author: In-cheol Choi, M.D., Department of Anesthesiology and Pain Medicine, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Pungnap 2-dong, Songpa-gu, Seoul 138-736, Korea. Tel: 82-2-3010-3862, Fax: 82-2-3010-6790, E-mail: [email protected] This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License ...
متن کاملIntra-aortic injection of propofol prevents spinal cord injury during aortic surgery.
OBJECTIVE We investigated whether propofol, a widely used anesthetic, injected into clamped aortic segments quickly attenuated transcranial spinal motor-evoked potential (MEP) amplitudes and protected against spinal cord injury during thoracoabdominal aortic surgery. METHODS Eighteen beagle dogs were divided into three groups (n=6, each group): group 1 (20 ml of saline, intra-aortic injection...
متن کاملStroke in surgery of the arteriosclerotic descending thoracic aortic aneurysms: influence of cross-clamping technique of the aorta.
OBJECTIVE The risk of stroke caused by dislodgment of loose atheromatous plaque or mural emboli is increased by cross-clamping of the aorta. Some patients undergo descending thoracic aortic aneurysm repair with proximal aortic cross-clamping between the left common carotid artery and the left subclavian artery. The objective of this study was to determine the influence of proximal aortic cross-...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesiology
دوره 104 5 شماره
صفحات -
تاریخ انتشار 2006