Microfabricated renewable beads-trapping/releasing flow cell for rapid antigen-antibody reaction in chemiluminescent immunoassay.

نویسندگان

  • Zhifeng Fu
  • Guocheng Shao
  • Jun Wang
  • Donglai Lu
  • Wanjun Wang
  • Yuehe Lin
چکیده

A renewable flow cell integrating a microstructured pillar-array filter and a pneumatic microvalve was microfabricated to trap and release beads. A bead-based immunoassay using this device was also developed. This microfabricated device consists of a microfluidic channel connecting to a beads chamber in which the pillar-array filter is built. Underneath the filter, there is a pneumatic microvalve built across the chamber. Such a device can trap and release beads in the chamber by "closing" or "opening" the microvalve. On the basis of the pneumatic microvalve, the device can trap beads in the chamber before performing an assay and release the used beads after the assay. Therefore, this microfabricated device is suitable for "renewable surface analysis". A model analyte, 3,5,6-trichloropyridinol (TCP), was chosen to demonstrate the analytical performance of the device. The entire fluidic assay process, including beads trapping, immuno binding, beads washing, beads releasing, and chemiluminesence signal collection, could be completed in 10 min. The immunoassay of TCP using this microfabricated device showed a linear range of 0.20-70 ng/mL with a limit of detection of 0.080 ng/mL. The device was successfully used to detect TCP spiked in human plasma at the concentration range of 1.0-50 ng/mL, with an analytical recovery of 81-110%. The results demonstrated that this device can provide a rapid, sensitive, reusable, low-cost, and automatic tool for detecting various biomarkers in biological fluids.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flow Injection Chemiluminescent Immunoassay for Carcinoembryonic Antigen Using Boronic Immunoaffinity Column

A flow injection chemiluminescence immunoassay for rapid and sensitive detection of carcinoembryonic antigen (CEA) by using a phenylboronic acid-based immunoaffinity column as a glycoprotein collector was proposed in this paper. The column was prepared by coupling of 3-aminophenylboronic acid on the glass beads through a γ-glycidoxypropyltrimethoxysilane (GPMS) linkage. Based on an indirect com...

متن کامل

Chemiluminescent immunosensor for CA19-9 based on antigen immobilization on a cross-linked chitosan membrane.

A novel chemiluminescent immunosensor for carbohydrate antigen 19-9 (CA19-9) based on the immobilization of CA19-9 on the cross-linked chitosan membrane was developed. The different membranes were characterized by atomic force microscopy (AFM) and infrared spectrum, respectively. Based on a noncompetitive immunoassay format, this proposed chemiluminescent immunosensor enabled a low-cost, flexib...

متن کامل

AlphaLISA immunoassays: the no-wash alternative to ELISAs for research and drug discovery

biotinylated antibody bound to streptavidin-coated donor beads and a second antibody conjugated to AlphaLISA acceptor beads. The binding of the two antibodies to the analyte brings donor and acceptor beads into proximity. Laser irradiation of donor beads at 680 nm generates a flow of singlet oxygen, triggering a cascade of chemical events in nearby acceptor beads, which results in a chemilumine...

متن کامل

Electrochemical immunoassay for vitellogenin based on sequential injection using antigen-immobilized magnetic microbeads.

A rapid and sensitive immunoassay for the determination of vitellogenin (Vg) is described. The method involves a sequential injection analysis (SIA) system equipped with an amperometric detector and a neodymium magnet. Magnetic beads, onto which an antigen (Vg) was immobilized, were used as a solid support in an immunoassay. The introduction, trapping and release of magnetic beads in an immunor...

متن کامل

Magnetically promoted rapid immunoreactions using functionalized fluorescent magnetic beads: a proof of principle.

BACKGROUND Accurate detection and monitoring of disease-related biomarkers is important in understanding pathophysiology. We devised a rapid immunoreaction system that uses submicrometer polymer-coated fluorescent ferrite (FF) beads containing both ferrites (magnetic iron oxide) and fluorescent europium complexes. METHODS FF beads were prepared by encapsulation of hydrophobic europium complex...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 83 7  شماره 

صفحات  -

تاریخ انتشار 2011