Impact of diastolic dysfunction severity on global left ventricular volumetric filling - assessment by automated segmentation of routine cine cardiovascular magnetic resonance
نویسندگان
چکیده
OBJECTIVES To examine relationships between severity of echocardiography (echo) -evidenced diastolic dysfunction (DD) and volumetric filling by automated processing of routine cine cardiovascular magnetic resonance (CMR). BACKGROUND Cine-CMR provides high-resolution assessment of left ventricular (LV) chamber volumes. Automated segmentation (LV-METRIC) yields LV filling curves by segmenting all short-axis images across all temporal phases. This study used cine-CMR to assess filling changes that occur with progressive DD. METHODS 115 post-MI patients underwent CMR and echo within 1 day. LV-METRIC yielded multiple diastolic indices - E:A ratio, peak filling rate (PFR), time to peak filling rate (TPFR), and diastolic volume recovery (DVR80 - proportion of diastole required to recover 80% stroke volume). Echo was the reference for DD. RESULTS LV-METRIC successfully generated LV filling curves in all patients. CMR indices were reproducible (< or = 1% inter-reader differences) and required minimal processing time (175 +/- 34 images/exam, 2:09 +/- 0:51 minutes). CMR E:A ratio decreased with grade 1 and increased with grades 2-3 DD. Diastolic filling intervals, measured by DVR80 or TPFR, prolonged with grade 1 and shortened with grade 3 DD, paralleling echo deceleration time (p < 0.001). PFR by CMR increased with DD grade, similar to E/e' (p < 0.001). Prolonged DVR80 identified 71% of patients with echo-evidenced grade 1 but no patients with grade 3 DD, and stroke-volume adjusted PFR identified 67% with grade 3 but none with grade 1 DD (matched specificity = 83%). The combination of DVR80 and PFR identified 53% of patients with grade 2 DD. Prolonged DVR80 was associated with grade 1 (OR 2.79, CI 1.65-4.05, p = 0.001) with a similar trend for grade 2 (OR 1.35, CI 0.98-1.74, p = 0.06), whereas high PFR was associated with grade 3 (OR 1.14, CI 1.02-1.25, p = 0.02) DD. CONCLUSIONS Automated cine-CMR segmentation can discern LV filling changes that occur with increasing severity of echo-evidenced DD. Impaired relaxation is associated with prolonged filling intervals whereas restrictive filling is characterized by increased filling rates.
منابع مشابه
Automated segmentation of routine clinical cardiac magnetic resonance imaging for assessment of left ventricular diastolic dysfunction.
BACKGROUND Cardiac magnetic resonance (CMR) is established for assessment of left ventricular (LV) systolic function but has not been widely used to assess diastolic function. This study tested performance of a novel CMR segmentation algorithm (LV-METRIC) for automated assessment of diastolic function. METHODS AND RESULTS A total of 101 patients with normal LV systolic function underwent CMR ...
متن کاملDetecting left ventricular impaired relaxation in cardiac MRI using moving mesh correspondences
UNLABELLED Anatomical cine cardiovascular magnetic resonance (CMR) imaging is widely used to assess the systolic cardiac function because of its high soft tissue contrast. Assessment of diastolic LV function has not regularly been performed due the complex and time consuming procedures. This study presents a semi-automated assessment of the left ventricular (LV) diastolic function using anatomi...
متن کاملEvaluation of left ventricular diastolic function by fractional area change using cine cardiovascular magnetic resonance: a feasibility study
BACKGROUND Evaluation of left ventricular (LV) diastolic function is essential for the management of heart failure. We verified whether LV diastolic function could be evaluated by measuring the fractional area change (FAC) using cine cardiovascular magnetic resonance (CMR). METHODS We collected clinical data from 59 patients who underwent echocardiography and cine CMR. Normal, impaired relaxa...
متن کاملCardiovascular magnetic resonance evaluation for left ventricular diastolic function: analysis of time-volume curve
Background Although cine magnetic resonance imaging (MRI) is considered the gold standard for evaluation of left ventricular (LV) volumes, mass, and systolic function, assessment of diastolic filling is still challenging. The aim of this study was to assess the impact of LV mass on diastolic function by time-volume curve obtained from cine MRI in patients with dilated cardiomyopathy (DCM) or hy...
متن کاملAn Automated 4D Approach for Left Ventricular Assessment in Clinical Cine MR Images
Cine Magnetic Resonance (MR) imaging has become the method-of-choice for the examination of the dynamic behaviour of the heart. An assessment of the left ventricle can reveal regions of myocardial dysfunction and their severeness. The scope of this work is a complete analysis of the left ventricular dynamics for the usage in a clinical environment. For that purpose, endocardial and epicardial b...
متن کامل