Tracer Studies at a Full-scale Lagoon Used as Pre-treatment Facility for a Water Treatment Plant

نویسنده

  • B. RUFFINO
چکیده

The water treatment plant (WTP) of Turin (Italy), fed by water of river, has a lagoon as pre-treatment facility. Since the effectiveness of the lagoon treatment towards the removal of contaminants from water depends on the residence time of the system, and the mixing aspects for the limitation of peak concentration are also very important, this led to an investigation of the internal hydraulics of the lagoon. A tracer study using sodium fluoride (NaF) was performed to determine the stimulus response output and an extensive internal sampling of the tracer was also performed to better understand the movement of the tracer through the system. The lagoon investigated in the study had a surface of 151600 m, a volume of about 1.8·10 m and a nominal residence time of 18 d at average daily flow (1150 L/s). An amount of NaF equal to 180 kg was diluted with about 50000 m of the lagoon water and introduced in the lagoon in 12 hours, in order to simulate a pulse injection. The amount of tracer added was fixed in order not to exceed the threshold concentration of 1.5 mg/L (maximum concentration value allowed in drinking water) under the hypothesis that the lagoon was not mixed at all (plug flow modality). Samples were taken from the outlet channel every 45 minutes and analyzed using a fluoride selective probe. The sampling campaign at the outlet channel was stopped after 29 days from the introduction of the tracer, when the outlet concentration dropped under the detection limit of the fluoride selective probe. Samples were also taken at 15 points (over 3 depth values, for a total of 45 sampling points) throughout the lagoon, 1, 7 and 14 days after the tracer introduction. From the interpretation of the tracer response and the tracer distribution in the lagoon in the three days of sampling, it appears that the system was efficiently mixed without relevant short circuits. In fact the first detection of the tracer at the outlet channel occurred after very few hours from the beginning of the test and the mean residence time of the lagoon, determined using the Levenspiel formula, in the presence of the flow rate used for the test, was about 13 days compared with a theoretical hydraulic residence time of 18 days. This assured that dissolved contaminants, like fluoride, from the river were efficiently diluted by the lagoon before entering the WTP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reduction of Ammonia Emissions from Treated Anaerobic Swine Lagoons

There is a need for treatment technologies that can effectively address environmental concerns associated with anaerobic lagoons typically used to manage manure. These technologies must be able to capture nutrients, kill pathogens, and reduce emissions of ammonia (NH ) and nuisance odors. To meet these needs, a wastewater treatment plant was demonstrated at full-scale in one of two 4,360-pig pr...

متن کامل

Egg wash wastewater: estrogenic risk or environmental asset?

Commercial production of eggs and egg products requires the washing of eggs to remove urinary-fecal material and broken egg residue. In the case of one Ohio farming facility, 1.6 million birds produce 1.4 million eggs per day, using approximately 50 mL of wash water/egg or approximately 70,000 L per day. The aqueous waste stream was evaluated for estrogenicity to determine if potential for endo...

متن کامل

Water quality improvements of wastewater from confined animal feeding operations after advanced treatment.

Current trends of animal production concentration and new regulations promote the need for environmentally safe alternatives to land application of liquid manure. These technologies must be able to substantially remove nutrients, heavy metals, and emissions of ammonia and odors and disinfect the effluent. A new treatment system was tested full-scale in a 4360-swine farm in North Carolina to dem...

متن کامل

Reduction of malodorous compounds from a treated swine anaerobic lagoon.

There is a need for treatment technologies that can eliminate environmental problems associated with anaerobic lagoons. These technologies must be able to capture nutrients, kill pathogens, and reduce emissions of ammonia and nuisance odors. To meet these needs, a full-scale wastewater treatment plant was installed as a demonstration project on one of three 4360-pig (Sus scrofa) production unit...

متن کامل

Efficiency of electrical coagulation process using aluminum electrodes for municipal wastewater treatment: a case study at Karaj wastewater treatment plant

Background: The reuse of treated municipal wastewater is an important source of water for different ,purposes. This study evaluated the efficiency of the electrocoagulation process in removing turbidity,a total suspended solids (TSS), chemical oxygen demand (COD), nitrate, and phosphate from wastewater at the treatment facility in Karaj, Iran. Methods: This experimental study was performed at ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013