Comparison of SpineJet XL and Conventional Instrumentation for Disk Space Preparation in Unilateral Transforaminal Lumbar Interbody Fusion.
نویسندگان
چکیده
OBJECTIVE Although unilateral transforaminal lumbar interbody fusion (TLIF) is widely used because of its benefits, it does have some technical limitations. Removal of disk material and endplate cartilage is difficult, but essential, for proper fusion in unilateral surgery, leading to debate regarding the surgery's limitations in removing the disk material on the contralateral side. Therefore, authors have conducted a randomized, comparative cadaver study in order to evaluate the efficiency of the surgery when using conventional instruments in the preparation of the disk space and when using the recently developed high-pressure water jet system, SpineJet XL. METHODS Two spine surgeons performed diskectomies and disk preparations for TLIF in 20 lumbar disks. All cadaver/surgeon/level allocations for preparation using the SpineJet XL (HydroCision Inc., Boston, MA, USA) or conventional tools were randomized. All assessments were performed by an independent spine surgeon who was unaware of the randomizations. The authors measured the areas (cm(2)) and calculated the proportion (%) of the disk surfaces. The duration of the disk preparation and number of instrument insertions and withdrawals required to complete the disk preparation were recorded for all procedures. RESULTS The proportion of the area of removed disk tissue versus that of potentially removable disk tissue, the proportion of the area of removed endplate cartilage, and the area of removed disk tissue in the contralateral posterior portion showed 74.5 +/- 17.2%, 18.5 +/- 12.03%, and 67.55 +/- 16.10%, respectively, when the SpineJet XL was used, and 52.6 +/- 16.9%, 22.8 +/- 17.84%, and 51.64 +/- 19.63%, respectively, when conventional instrumentations were used. The results also showed that when the SpineJet XL was used, the proportion of the area of removed disk tissue versus that of potentially removable disk tissue and the area of removed disk tissue in the contralateral posterior portion were statistically significantly high (p < 0.001, p < 0.05, respectively). Also, compared to conventional instrumentations, the duration required to complete disk space preparation was shorter, and the frequency of instrument use and the numbers of insertions/withdrawals were lower when the SpineJet XL was used. CONCLUSION The present study demonstrates that hydrosurgery using the SpineJet XL unit allows for the preparation of a greater portion of disk space and that it is less traumatic and allows for more precise endplate preparation without damage to the bony endplate. Furthermore, the SpineJet XL appears to provide tangible benefits in terms of disk space preparation for graft placement, particularly when using the unilateral TLIF approach.
منابع مشابه
Finite Element Analysis of a New Pedicle Screw-Plate System for Minimally Invasive Transforaminal Lumbar Interbody Fusion
PURPOSE Minimally invasive transforaminal lumbar interbody fusion (MI-TLIF) is increasingly popular for the surgical treatment of degenerative lumbar disc diseases. The constructs intended for segmental stability are varied in MI-TLIF. We adopted finite element (FE) analysis to compare the stability after different construct fixations using interbody cage with posterior pedicle screw-rod or ped...
متن کاملProgress, Challenges And Opportunities In Disc Space Preparation For Lumbar Interbody Fusion
Lumbar interbody fusion from a posterior approach affords the advantage of adding interbody fusion to a posterolateral fusion while avoiding the added morbidity of an anterior approach to the spine. Transforaminal lumbar interbody fusion (TLIF) provides anterior column support through a single posterolateral approach to the disc space with minimal neural retraction and disruption of only one fa...
متن کاملInstrumented transforaminal lumbar interbody fusion in surgical treatment of recurrent disc herniation
Background :The incidence of recurrence in patients undergoing primary discectomy due to lumbar disc herniation (LDH), is regularly reported as 5-15%. In this study we aimed to evaluate surgical outcome of instrumented transforaminal lumbar interbody fusion (TLIF) in the patients suffering from recurrent LDH. Methods : We retrospectively studied 51 patients (30 female, 21 male) from August ...
متن کاملThe role of cage height on the flexibility and load sharing of lumbar spine after lumbar interbody fusion with unilateral and bilateral instrumentation: a biomechanical study
BACKGROUND One- and two-level lumbar interbody fusion with unilateral instrumentation is as effective as that with bilateral instrumentation. The height of the interbody cage influences the operated segment stability and the fusion technique success. The purpose of this research was to determine the effect of the fusion cage height (i.e. long and short) on both the stability (based on flexibili...
متن کاملIs one cage enough in posterior lumbar interbody fusion: a comparison of unilateral single cage interbody fusion to bilateral cages.
Posterior lumbar interbody fusion (PLIF), as recommended with bilateral lumbar interbody cages and pedicle screw fixation, has increased the successful fusion rate to nearly 100%. Presently, a unilateral approach to the disc space with a variant of PLIF, the trans-foraminal interbody fusion is often used. There are few clinical studies of unilateral interbody fusion. The clinical and fusion res...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of Korean Neurosurgical Society
دوره 47 5 شماره
صفحات -
تاریخ انتشار 2010