Quantifying relative afferent pupillary defects using a Sbisa bar.

نویسندگان

  • A McCormick
  • R Bhola
  • L Brown
  • D Squirrel
  • J Giles
  • I Pepper
چکیده

AIM To compare the Sbisa bar (Bagolini filter bar) with neutral density filters (NDF) in quantifying relative afferent pupillary defects (RAPD). METHODS 11 patients with a RAPD were graded and a neutral density filter bar was used to quantify the RAPD. This was repeated using the Sbisa bar. The Sbisa bar (Bagolini filter bar) is used by orthoptists to quantify density of suppression in amblyopia and is of a similar construct to NDFs. Before this clinical part of the study the luminance for each filter was measured, which enabled a direct comparison to be made. RESULTS In the analysis of patients with RAPD a high correlation was found when comparing the Sbisa and NDF bars r = 0.95. This was statistically significant (p = <0.001). Correlation was also high when the luminance values for the filters were substituted for the clinical readings (r = 0.92; p=<0.001). CONCLUSION The Sbisa bar is a comparable instrument to the NDF bar in measuring RAPD. Its availability in the clinical situation makes it a practical choice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification of relative afferent pupillary defects induced by posterior sub-Tenon's, peribulbar, and retrobulbar anaesthetics.

AIMS The effect of local anaesthetics on optic nerve function can be investigated by quantifying the relative afferent pupillary defect (RAPD). METHODS The study compared the depth of induced RAPD following posterior sub-Tenon's, retrobulbar, and peribulbar local anaesthetics using crossed polarising filters before cataract surgery (time 1 = 5 minutes), immediately after surgery (time 2 = 42 ...

متن کامل

Pupillographic characteristics of simulated relative afferent pupillary defects.

Relative afferent pupillary defects were simulated in normal individuals by performing the alternating light test while dimming the light in front of one eye with neutral density filters. Pupillary responses were elicited using a binocular photostimulator and recorded using a binocular television pupillometer. In five subjects, four spatial variables of the pupillary response--contraction ampli...

متن کامل

Isolated relative afferent pupillary defect secondary to contralateral midbrain compression.

BACKGROUND Relative afferent pupillary defects are typically related to ipsilateral lesions within the anterior visual pathways. OBJECTIVE To describe a patient who had a workup for headache and was found to have an isolated left relative afferent pupillary defect without any other neurological findings. DESIGN We review the neuroanatomy of the pupillary light reflex pathway and emphasize t...

متن کامل

Focal loss volume best differentiates eyes with afferent pupillary defect

Purpose: To quantify the specificity and sensitivity of RTVue-100, Optovue parameters at determining the presence of a relative afferent pupillary defect (RAPD) by coupling their values with the instrument normative data base (NDB) and the presence of a RAPD. To generate the distribution for the focal loss volume (FLV) percentage, by coupling its value to the instrument NDB and presence of a RA...

متن کامل

Fourth nerve paresis and ipsilateral relative afferent pupillary defect without visual sensory disturbance. A sign of contralateral dorsal midbrain disease.

We describe a patient with a left trochlear nerve paresis and a left relative afferent pupillary defect despite normal visual acuity, color vision, visual fields, and fundus examination. Magnetic resonance imaging revealed a lesion in the right dorsal midbrain extending from the brachium of the superior colliculus to the inferior colliculus. The anatomy and physiology of the pupillary light ref...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 86 9  شماره 

صفحات  -

تاریخ انتشار 2002