The Effects of Electrical Degradation on the Microstructure of Metal Oxide Varistor
نویسندگان
چکیده
-In this paper, the findings from systematic experiments with the purpose to determine the degradation effect of single and multiple current pulses on the microstructure of the Metal Oxide (MO) varistor are described. Six distribution class varistors from one manufacturer were used in these experiments. The first part of the paper describes the electrical condition after application of single and multiple lightning current pulses. The results (before and after each elevated current impulse test) of 1mA AC reference voltage and residual voltage are presented in this section. We have also investigated a new technique called “Return Voltage Measurement” for monitoring of the degradation in MO varistors. This is described in detail. The second part deals with the microstructure observations of MO varistors. The results of microstructural examination of impulse current on MO varsitors are examined in detail. This section also explains the relationship between the microstructural changes and electrical degradation of MO varistors.
منابع مشابه
Influence of Adding SiC on Microstructure and Electrical Properties of ZnO-based Nanocomposite Varistor
In this research the influence of adding SiC on microstructure and electrical properties of ZnO-based Nanocomposite varistors were investigated. SiC was added with amounts of 10-0 mass% to ZnO-based varistor composition. It is found that SiC allows reaching to high threshold voltage with formation of fine-graine...
متن کاملThe effect of composition on flash sintering parameters of varistors based on ZBS
Flash sintering is one of the latest sintering processes of ceramics, which has recently attracted the attention of researchers due to its high sintering speed and significant energy reduction. An essential feature of successful flash is negative temperature coefficient (NTC) semiconductor behavior. In this research, the flash sinter process of ceramic varistor based on ZnO-Bi2O3-Sb2O3 (ZBS) ha...
متن کاملA Comparative Study of Thermal Conductivity in ZnO- and SnO2-Based Varistor Systems
We performed a comparative study of electrical and thermal properties of ZnOand SnO2-based varistor. The electrical properties of commercial ZnO-based varistor are equivalent to that found in SnO2-based varistor system. In spite of this, the SnO2 showed a thermal conductivity higher than commercial samples of ZnO-based varistor, which allied with its simpler microstructure and lower dopant conc...
متن کاملCondition Assessment of Metal Oxide Surge Arrester Based on Multi-Layer SVM Classifier
This paper introduces the indicators for surge arrester condition assessment based on the leakage current analysis. Maximum amplitude of fundamental harmonic of the resistive leakage current, maximum amplitude of third harmonic of the resistive leakage current and maximum amplitude of fundamental harmonic of the capacitive leakage current were used as indicators for surge arrester condition mon...
متن کاملModelling of Metal Oxide Surge Arresters in Simulation Software DYNAST
This paper describes the possibilities for mathematical modelling of gap-less surge arresters in the simulation software DYNAST. This tool does not belong to standard modelling softwares in the field of electric power engineering. However, it may provide some key advantages when compared to more frequently used software such as EMTP-ATP and MATLAB-Simulink. Description of the metal oxide varist...
متن کامل