Ratiometric nanomolar detection of Cu2+ ions in mixed aqueous media: a Cu2+/Li+ ions switchable allosteric system based on thiacalix[4]crown.

نویسندگان

  • Manoj Kumar
  • Naresh Kumar
  • Vandana Bhalla
چکیده

A novel ditopic fluorescent chemosensor 2, based on the 1,3-alternate conformation of thiacalix[4]crown possessing two complexation sites, was synthesized and shows ratiometric nanomolar detection of Cu(2+) ions and exhibits negative allosteric behaviour between Cu(2+)/Li(+) ions in mixed aqueous media.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ratiometric detection of Hg2+ ions: an allosterically synchronized Hg2+/Li+ switch based on thiacalix[4]crown.

A new heteroditopic chemosensor based on the 1,3-alternate conformation of thiacalix[4]crown shows a ratiometric fluorescence response towards Hg(2+) ions. Further, a negative allosteric behaviour between Hg(2+)/Li(+) ions is observed. Thus, metal ion exchange triggers a Hg(2+)/Li(+) switchable fluorescent chemosensor.

متن کامل

Peptide-Mediated Nanopore Detection of Uranyl Ions in Aqueous Media

Uranium is one of the most common radioactive contaminants in the environment. As a major nuclear material in production, environmental samples (like soil and groundwater) can provide signatures on uranium production activity inside the facility. Thus, developing a new and portable analytical technology for uranium in aqueous media is significant not only for environmental monitoring, but also ...

متن کامل

Fabrication and characterization of polycarbonate/titanium oxide nanotubes mixed matrix membranes for efficient removal of cadmium and copper from aqueous solution

In this study, novel polycarbonate-titanium oxide nanotubes (PC-TNT) ultrafiltration mixed matrix membranes (MMMs) were fabricated for decontamination of Cd2+ and Cu2+ metal ions from aqueous solution. The weight percent of TNTs in the polycarbonate membrane matrix was changed from 0 to 15. The synthesized neat PC membrane and PC-TNTs MMMs were characterized with respect to structural morpholog...

متن کامل

Nanomolar-level selective dual channel sensing of Cu2+ and CN- from an aqueous medium by an opto-electronic chemoreceptor.

A dual-channel chromogenic and fluorogenic fused-aromatic-system-based chemoreceptor (2-(benzo[d]thiazol-2-yl)-1-((pyren-8-yl)methylene)hydrazine) (TyM) was designed for ditopic sensitivity towards heavy and transition metal ions (HTMs), such as Cu2+, in an aqueous medium and lethal CN- in a semi-aqueous medium. The chemoreceptor displayed proclivity towards the targeted analytes with a distinc...

متن کامل

Water Soluble Cationic Porphyrin Sensor for Detection of Hg2+, Pb2+, Cd2+, and Cu2+

Here we report the sensing properties of the aqueous solution of mesotetra(N-methyl-4-pyridyl)porphine tetrachloride (1) for simultaneous detection of toxic metal ions by using UV-vis spectroscopy. Cationic porphyrin 1 displayed different electronic absorptions in UV-vis region upon interacting with Hg2+, Pb2+, Cd2+, and Cu2+ ions in neutral water solution at room temperature. Quite interesting...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Dalton transactions

دوره 41 34  شماره 

صفحات  -

تاریخ انتشار 2012