Early versus Delayed Insertion of Intrauterine Contraception after Medical Abortion — A Randomized Controlled Trial

نویسندگان

  • Ingrid Sääv
  • Olof Stephansson
  • Kristina Gemzell-Danielsson
چکیده

BACKGROUND Today, a large proportion of early abortions are medical terminations, in accordance to the woman's choice. Intrauterine contraceptives (IUC) provide highly effective, reversible, long-acting contraception. However, the effects of timing of IUC insertion after medical abortion are not known. METHODS Women undergoing medical abortion with mifepristone and misoprostol up to 63 days gestation and opting for IUC were randomised to early insertion (day 5-9 after mifepristone) or delayed (routine) insertion (at 3-4 weeks after mifepristone). The primary outcome was the rate of IUC expulsion at six months after IUC insertion. RESULTS A total of 129 women were randomized, and 116 women had a successful IUC insertion. There was no difference in expulsion rate between early (9.7%) vs. delayed (7.4%) IUC insertion (risk difference -9.2-13.4). Furthermore, 1.5% of women randomized to early and 11.5% to delayed insertion did not attend the follow up (proportion difference 10.0%, 95% CI: 1.8-20.6%, p = 0.015), and a higher proportion of women (41%) had had unprotected intercourse prior to returning for insertion in the delayed group compared with the early group (16%) (p = 0.015). Adverse events were rare and did not differ between the groups. CONCLUSIONS Early insertion of IUC after medical abortion was safe and well tolerated with no increased incidence for expulsions or complications. Women were more likely to return for the IUC insertion if scheduled early after the abortion, and less likely to have had an unprotected intercourse prior to the IUC insertion. Early insertion should be offered as a routine for women undergoing first trimester medical abortion. TRIAL REGISTRATION ClinicalTrials.gov NCT01537562.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Immediate vs. delayed insertion of intrauterine contraception after second trimester abortion: study protocol for a randomized controlled trial

BACKGROUND We describe the rationale and protocol for a randomized controlled trial (RCT) to assess whether intrauterine contraception placed immediately after a second trimester abortion will result in fewer pregnancies than current recommended practice of intended placement at 4 weeks post-abortion. Decision analysis suggests the novel strategy could substantially reduce subsequent unintended...

متن کامل

Timing of copper intrauterine device insertion after medical abortion: a randomized controlled trial.

OBJECTIVE To compare intrauterine device (IUD) use at 6 months in women randomized to receive an intrauterine copper contraceptive 1 week compared with 1 month after medical abortion. METHODS We recruited women undergoing medical abortion with mifepristone and misoprostol and choosing the copper IUD for contraception. We randomly assigned participants to "immediate" insertion 1 week after mif...

متن کامل

What proportion of Canadian women will accept an intrauterine contraceptive at the time of second trimester abortion? Baseline data from a randomized controlled trial.

OBJECTIVE This report details enrolment findings related to a Canadian randomized controlled trial comparing immediate to delayed intrauterine contraception (IUC) placement after a second trimester abortion. We report acceptance of IUC, satisfaction with prior contraception, adherence to the CONSORT criteria, and challenges faced in the recruitment process. METHODS Women seeking second trimes...

متن کامل

Women’s satisfaction in early versus delayed postcaesarean feeding: A one-blind randomized controlled trial study

 Background: The early postoperative feeding after caesarean section (C- section) has remained controversial. This study was designed to evaluate the safety and efficacy of early versus delayed postcaesarean section oral feeding regarding gastrointestinal complications and patients postoperative satisfaction after C- section. Methods: This clinical trial study was conducted on 200 p...

متن کامل

Expulsion and continuation rates after postabortion insertion of framed IUDs versus frameless IUDs – review of the literature

Background Early intrauterine device (IUD) discontinuation after insertion immediately following aspiration abortion or after early medical abortion occurs as a consequence of expulsion of the IUD or removal due to side effects. These are often the consequence of the uterine forces impacting on the IUD due to spatial discrepancy with the uterine cavity causing pain, abnormal bleeding, and event...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2012