A New Method for Evaluating Moisture Content and Aging Degree of Transformer Oil-Paper Insulation Based on Frequency Domain Spectroscopy
نویسندگان
چکیده
The condition of oil-paper insulation is closely related to the life expectancy of a transformer. The accurate results of oil-paper have not been obtained due to the impact of influencing factors. Therefore, in order to improve the evaluation accuracy of oil-paper insulation, in this paper, oil-paper samples which were prepared with different aging and moisture content were analyzed by frequency domain spectroscopy (FDS). Results show that when the moisture content is less than 2%, the range of 101~103 Hz is mainly affected by moisture and aging has little effect. However, with the increase of moisture content, the effect of aging degree on this band became increasingly prominent. Sm, which represents the integral value from 10−1 to 10−3 Hz, and SDP, which represents the integral value from 101 to 103 Hz, were extracted as characteristic parameters of moisture content and aging degree respectively. Compensation factors γ which represents the influence ratio of moisture on SDP and φ which represents the influence ratio of aging on Sm were introduced to compensate for the influence of moisture content and aging degree on characteristics respectively. Then, a new method was proposed to evaluate the condition of oil-paper based on compensation factors. Through this method, the influence in characteristics can be eliminated by the obtained actual compensation factors, thus distinguishing the internal influence between moisture content and aging degree on FDS. Finally, this method was verified by field test.
منابع مشابه
Estimation of Moisture in Transformer Insulation Using Dielectric Frequency Response Analysis by Heuristic Algorithms
Transformers are one of the most valuable assets of power systems. Maintenance and condition assessment of transformers has become one of the concerns of researchers due to huge number of transformers has been approached to the end of their lifetimes. Transformer’s lifetime depends on the life of its insulation and the insulation’s life is strongly influenced by its moisture attraction as well....
متن کاملStudy of the Impact of Initial Moisture Content in Oil Impregnated Insulation Paper on Thermal Aging Rate of Condenser Bushing
This paper studied the impact of moisture on the correlated characteristics of the condenser bushings oil-paper insulation system. The oil-impregnated paper samples underwent accelerated thermal aging at 130 ̋C after preparation at different initial moisture contents (1%, 3%, 5% and 7%). All the samples were extracted periodically for the measurement of the moisture content, the degree of polym...
متن کاملOn the Feasibility of Using Poles Computed from Frequency Domain Spectroscopy to Assess Oil Impregnated Paper Insulation Conditions
Frequency Domain Spectroscopy (FDS) is an effective tool allowing assessing the condition of oil-paper insulation system in power equipment. However, results from these measurements are known to be greatly influenced by various parameters, including insulation aging, moisture content, and insulation geometry/volume, together with environmental condition such as temperature. In this contribution...
متن کاملReview of Modern Diagnostic Techniques for Assessing Insulation Condition in Aged Transformers
Cellulosic paper and oil insulation in a transformer degrade at higher operating temperatures. Degradation is accelerated in the presence of oxygen and moisture. Power transformers being expensive items need to be carefully monitored throughout its operation. Well established time-based maintenance and conservative replacement planning is not feasible in a current market driven electricity indu...
متن کاملICSD 2007 – International Conference on Solid Dielectrics ( 9 th IEEE
The measurement of oil-paper insulation systems in the frequency domain provides novel diagnostic methods for quality control of materials and highvoltage power transformers. The first task is to measure and to analyse the dielectric behaviour of oil-paper insulation systems and their dependency on material quality, moisture content and ageing products in oil, paper and pressboard. Furthermore,...
متن کامل