Microcantilever biosensors based on conformational change of proteins.
نویسندگان
چکیده
Microcantilevers (MCLs) hold a position as a cost-effective and highly sensitive sensor platform for medical diagnostics, environmental analysis and fast throughput analysis. MCLs are unique in that adsorption of analytes on the microcantilever (MCL) surface changes the surface characteristics of the MCL and results in bending of the MCL. Surface stress due to conformation change of proteins and other polymers has been a recent focus of MCL research. Since conformational changes in proteins can be produced through binding of anylates at specific receptor sites, MCLs that respond to conformational change induced surface stress are promising as transducers of chemical information and are ideal for developing microcantilever-based biosensors. The MCL can also potentially be used to investigate conformational change of proteins induced by non-binding events such as post-translational modification and changes in temperature or pH. This review will provide an overview of MCL biosensors based on conformational change of proteins bound to the MCL surface. The models include conformational change of proteins, proteins on membranes, enzymes, DNA and other polymers.
منابع مشابه
Improved surface modification approach for micromechanical biosensors.
We have investigated the sensing performance of protein-based microcantilever biosensors prepared from multiple surface conjugation chemistries. The 11-mercaptoundecanoic acid monolayers were prepared according to both traditional and modified processes. In three protein-based biosensors, the modified process improved microcantilever sensing performance by increasing the bending amplitude, a cr...
متن کاملEffect of Conformational Entropy on the Nanomechanics of Microcantilever-Based Single-Stranded DNA Sensors
An entropy-controlled bending mechanism is presented to study the nanomechanics of microcantilever-based single-stranded DNA (ssDNA) sensors. First; the conformational free energy of the ssDNA layer is given with an improved scaling theory of thermal blobs considering the curvature effect; and the mechanical energy of the non-biological layer is described by Zhang’s two-variable method for lami...
متن کاملOrganophosphorus hydrolase multilayer modified microcantilevers for organophosphorus detection.
We report a biosensor based on organophosphorus hydrolase (OPH) multilayer modified microcantilever (MCL) for detection of organophosphorus compounds (OPs). The assay is based on substrate-dependent bending of the OPH functionalized MCLs. The cantilever bending amplitude at equilibrium was a function of the concentration of paraoxon with the dynamic range extending from 10(-7) to 10(-3)M. The l...
متن کاملNanomechanical microcantilever operated in vibration modes with use of RNA aptamer as receptor molecules for label-free detection of HCV helicase.
We report the nanomechanical microcantilevers operated in vibration modes (oscillation) with use of RNA aptamers as receptor molecules for label-free detection of hepatitis C virus (HCV) helicase. The nanomechanical detection principle is that the ligand-receptor binding on the microcantilever surface induces the dynamic response change of microcantilevers. We implemented the label-free detecti...
متن کاملCalculation of Stress And Deflection In Double Layer Microcantilever For Biosensor Application
In microcantilever-based biosensor, a sensitive layer plays an important role as a place for the establishment of functional layer for detecting molecules target. When a sensitive layer is coated on the microcantilever surface, a surface stress change is induced as a consequence of adsorbate-surface interaction, resulting in a deflection of the microcantilever. However, the microcantilever with...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Analyst
دوره 133 4 شماره
صفحات -
تاریخ انتشار 2008