Technique for detecting serial topographic changes in the optic disc and peripapillary retina using scanning laser tomography.
نویسندگان
چکیده
PURPOSE To describe and evaluate a new statistical technique for detecting topographic changes in the optic disc and peripapillary retina measured with confocal scanning laser tomography. METHODS The 256x256-pixel array of topographic height values obtained with each image from the Heidelberg Retina Tomograph (Heidelberg Engineering, Heidelberg, Germany) was divided into an array of 64x64 superpixels, where each superpixel contained 16 (i.e., 4x4) pixels. An analysis of variance technique was developed to analyze each superpixel with three baseline and three follow-up images. The performance of the technique was tested with and without adjustment for spatial correlation of topographic values using computer simulations and with real data from a normal control subject and a patient with progressive glaucomatous disc change. RESULTS Computer simulation with fixed population means and variance, and varying spatial correlation showed a monotonically increasing number of superpixels with significant test results (false positives), with 20% false-positives when the spatial correlation was 0.8 (the approximate median value in real patient data). The number of false-positive results was similar (17%) in serial images of a normal subject. When corrected for spatial correlation, the number of false-positives was independent of the level of spatial correlation and remained at the expected value of less than 5% in both simulations and real data. Although the number of significant test results in the patient with progressive glaucoma decreased after correction for spatial correlation, the change was readily apparent. Statistical power to detect mean differences in topographic values ranging from 0.5 to 4.0 SDs in computer simulation showed low power for changes of 1 SD or less, but increased dramatically with larger changes. CONCLUSIONS This technique has a high level of sensitivity to detect changes in the optic disc while maintaining a high level of specificity.
منابع مشابه
Relation of optic disc topography and age to thickness of retinal nerve fibre layer as measured using scanning laser polarimetry, in normal subjects.
AIMS To evaluate the relation of the optic nerve head topographic measurements and age with the thickness of the retinal nerve fibre layer (RNFL) in normal Caucasoid subjects by means of scanning laser polarimetry and tomography. METHODS Topographic optic disc measurements and RNFL thickness values of 38 normal Caucasoid subjects of both sexes aged 20 to 78 were measured using a confocal scan...
متن کاملPeripapillary Intrachoroidal Cavitation and Optic Pit in a Case of High Myopia and Glaucoma
Purpose: To report a case of peripapillary intrachoroidal cavitation (choroidal schisis) and optic pit in a case of high myopia and open-angle glaucoma. Case report: A 30-year-old high myopic man was referred to our clinic for presumed peripapillary choroidal tumors. In funduscopy, there were two yellow-orange and slightly elevated peripapillary lesions in both eyes with indistinct margins. A s...
متن کاملOptic disc topographic parameters measured in the normal cynomolgus monkey by confocal scanning laser tomography.
AIM To study optic disc topographic parameters in normal cynomolgus monkeys by Heidelberg retina tomograph (HRT). METHODS 12 optic disc topographic parameters were investigated in 36 normal eyes in 18 male monkeys. Mean (SD) and interocular differences were obtained for each parameter from three independent measurements made during a 1 week period. Correlations among the topographic parameter...
متن کاملUse of scanning laser ophthalmoscopy to monitor papilloedema in idiopathic intracranial hypertension.
AIMS To determine the sensitivity of confocal scanning laser ophthalmoscopy (SLO) in detecting clinically significant changes in papilloedema secondary to idiopathic intracranial hypertension (IIH) and the correlation with visual field loss. METHODS Eight patients--three new, two recurrent, and three chronic cases of IIH--were examined over a 9 month period with SLO (Heidelberg retina tomogra...
متن کاملMorphometric analysis of human peripapillary retinal nerve fiber layer thickness.
PURPOSE The peripapillary retinal nerve fiber layer (RNFL) thickness pattern in the normal human eye has been well characterized using data obtained with scanning laser polarimetry and optical coherence tomography. The authors sought to characterize the normative peripapillary RNFL thickness and pattern using histologic sections obtained from healthy postmortem human eyes. METHODS Seventeen u...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 41 3 شماره
صفحات -
تاریخ انتشار 2000