Measurement of the eye’s near infrared wave-front aberration using the objective crossed-cylinder aberroscope technique

نویسندگان

  • Norberto López-Gil
  • Howard C. Howland
چکیده

We used the crossed-cylinder aberroscope technique to obtain the near infrared (784 nm) wave-front aberration of the human eye. We compared the results with those obtained under the same conditions using red light (633 nm). Other than the greater retinal scattering of the near infrared light, third- and fourth-order wave-front aberrations are similar in both wavelengths. Values of the calculated near infrared point spread function show a typical half-height width of around 2 arcmin, which is in good agreement with previous work.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the accuracy of the crossed-cylinder aberroscope technique.

Simulations of the optics of the Howland crossed-cylinder aberroscope technique show that errors in alignment, data collection, and analysis can lead to unexpected asymmetries of the determined aberrations in a rotationally symmetric system. In particular, coma can be incorrectly indicated. The magnitude of the error in aberration measurement depends on the magnitude of the alignment, data coll...

متن کامل

Generation of third-order spherical and coma aberrations by use of radically symmetrical fourth-order lenses.

We have extended the method of Alvarez [J. Am. Optom. Assoc. 49, 24 (1978)] to generate a variable magnitude of third-order spherical and/or coma aberration by using a combination of fourth-order plates with a magnification system. The technique, based on the crossed-cylinder aberroscope, is used to measure the wave-front aberration generated by the plates. The method has been applied to correc...

متن کامل

The history and methods of ophthalmic wavefront sensing.

I t was once observed that the Russo-Japanese war of 1904-1905—with the introduction of high-speed bullets that made discrete lesions in the brains of the persons they intersected—did more for the understanding of brain function than any number of research efforts before that time. In the same vein, I submit that refractive surgery has done more for the once neglected and esoteric field of mono...

متن کامل

Measurement of monochromatic ocular aberrations of human eyes as a function of accommodation by the howland aberroscope technique

Further development of the objective version of the Howland and Howland [(1976) Science, 193, 580-582; (1977) Journal of the Optical Society of America, 67, 1508-1518] aberroscope technique for measuring ocular aberrations is described. Compensation for refractive corrections and calibration is discussed. The technique was used to investigate the effect of accommodation upon the monochromatic a...

متن کامل

Analysis of higher-order aberrations in a large clinical population.

PURPOSE To use a large wave-front database of a clinical population to investigate relationships between refractions and higher-order aberrations and between aberrations of right and left eyes. METHODS Third- and fourth-order aberration coefficients and higher-order root-mean-squared aberrations (HO RMS), scaled to a pupil size of 4.5-mm diameter, were analyzed in a population of approximatel...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Vision Research

دوره 39  شماره 

صفحات  -

تاریخ انتشار 1999