Theoretical and experimental evaluation of detached endcaps for 3 T birdcage coils.

نویسندگان

  • Marcello Alecci
  • Christopher M Collins
  • James Wilson
  • Wanzhan Liu
  • Michael B Smith
  • Peter Jezzard
چکیده

The use of detached endcaps for 3 T birdcage coils was investigated both theoretically and experimentally. Finite difference time domain analysis, along with workbench and MRI techniques, were used to map the radiofrequency (RF) B(1) distribution along the coil axis with and without an endcap. Without an endcap the measured B(1) value at the service end of the birdcage was only 45% of the value at the coil's center. This was improved to 85% with a detached endcap of maximum achievable diameter (375 mm), positioned 4 mm from the RF shield. The B(1) field distribution on the patient side of the coil was unaffected by the presence of the endcap. The dependence of the B(1) distribution as a function of endcap diameter was also investigated. Surprisingly, simulations and experiments show that there is an optimum ratio of endcap-to-birdcage coil diameter (approximately 1.08) that gives the best B(1) homogeneity. In the human head the optimized endcap, positioned 16 mm from the RF shield, improves the MRI signal amplitude from 55% to 85% of maximum toward the service end. This novel endcap design is easy to implement with existing birdcage coils, and could prove useful when flexibility in access to the RF coil is required.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and numerical evaluation of a volume coil array for parallel MR imaging at ultrahigh fields.

In this work, we propose and investigate a volume coil array design method using different types of birdcage coils for MR imaging. Unlike the conventional radiofrequency (RF) coil arrays of which the array elements are surface coils, the proposed volume coil array consists of a set of independent volume coils including a conventional birdcage coil, a transverse birdcage coil, and a helix birdca...

متن کامل

Numerical Comparison Between TEM Head Coil and Birdcage Head Coil at 7T

G. D. DeMeester, Z. Zhai, M. A. Morich, C. Leussler, C. Findeklee Philips Medical Systems, Cleveland, Ohio, United States, Philips Research Laboratories, Hamburg, Hamburg, Germany Introduction A TEM T/R head coil and a shielded birdcage T/R head coil operated at 298MHz/7T were both modeled using the Finite Difference Time Domain (FDTD) method. The two coils have approximately the same physical ...

متن کامل

Transceiver double crossed saddle for rodents at 2T

Introduction: Small animal MR imaging and spectroscopy, where spatial resolution is a limiting factor, requires the use of distinct transmit and receive coils [1]. This approach makes easier the optimization of the RF field homogeneity for transmit-only coils and signal-to-noise ratio (SNR) for receive-only coils. It also requires that RF coils should be electrically decoupled, commonly using P...

متن کامل

BirdcageBuilder: Design of Specified-Geometry Birdcage Coils with Desired Current Pattern and Resonant Frequency.

A simple method for birdcage coil design (high pass, low pass, and band pass) is presented. Rather than iteratively approaching the Larmor resonant frequency with known capacitances and calculated inductances, a more versatile approach to birdcage coil design is developed and validated, in which the necessary capacitances are calculated using a desired current pattern, a calculated inductance, ...

متن کامل

Comparison of simulated parallel transmit body arrays at 3 T using excitation uniformity, global SAR, local SAR, and power efficiency metrics.

PURPOSE We compare the performance of eight parallel transmit (pTx) body arrays with up to 32 channels and a standard birdcage design. Excitation uniformity, local specific absorption rate (SAR), global SAR, and power metrics are analyzed in the torso at 3 T for radiofrequency (RF)-shimming and 2-spoke excitations. METHODS We used a fast cosimulation strategy for field calculation in the pres...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 49 2  شماره 

صفحات  -

تاریخ انتشار 2003