AIM Due to new medical knowledge and legal restrictions, it is increasingly difficult to run a traditional allogenic bone bank so that alternative bone substitutes and methods of processing are being sought worldwide. METHOD In a prospective clinical study, the biological efficacy of thermodisinfected and then cryopreserved allogenic bank bone was investigated in 19 acetabular revisions in 18 patients. Simultaneously a newly developed titanium reconstruction ring was used. Any revision was regarded as an end point and the follow-up with radiological and clinical results were recorded. RESULTS The mean follow-up period was 8.1 (7.9 - 9.8) years. The patients were 73.5 years old (46 - 91) at the time of the revision surgery. One case had a septic course necessitating revision surgery. The other cases showed increasing homogeneity compared to the opposite side and gradual adaptation to the radiological structures found there beforehand. Screw breakage was observed in 3 cases but no implant failure, migration tendency or change in the position of the reconstruction ring or PE-cup. CONCLUSION Despite the low case numbers and different baseline situations, it can be concluded that thermodisinfected cancellous bone chips enable similarly good acetabular reconstruction as the routinely tried and tested cryoconserved, non-processed bone bank allograft, which is becoming increasingly difficult to obtain because of altered guidelines and legislation. The newly developed reconstruction ring has proven itself because of the improved range of sizes and the possibility of adjustment to the anatomical circumstances together with its outstanding material characteristics in clinical use.
منابع مشابه
Revision total hip arthroplasty using a Kerboull-type acetabular reinforcement device with bone allograft: minimum 4.5-year follow-up results and mechanical analysis.
We retrospectively reviewed 40 hips in 36 patients who had undergone acetabular reconstruction using a titanium Kerboull-type acetabular reinforcement device with bone allografts between May 2001 and April 2006. Impacted bone allografts were used for the management of American Academy of Orthopaedic Surgeons Type II defects in 17 hips, and bulk bone allografts together with impacted allografts ...
متن کامل6 years follow-up of hip revision surgery.
Revision total hip arthroplasty often presents surgeons with difficult bone loss problems. The purpose of this study was to evaluate the results of hip revision surgery according to bone stock We evaluated, in a retrospective study, 148 hip revision surgeries during 2004 to 2010. The Harris Hip Score (HHS), the acetabular cementation, the AAOS classification, the SOFCOT 99 bone loss grading and...
متن کاملFailure of structural acetabular allografts in cementless revision hip arthroplasty.
We investigated the radiographic and clinical course of 31 patients in whom a bulk acetabular allograft had been used during the cementless revision of a total hip replacement. Two patients died and two were lost to follow-up within 24 months, but of the remaining 27 acetabular components, 12 (44%) showed radiographic evidence of instability at a mean of 46 months. Five of these have been revis...
متن کاملAcetabular reconstruction with impacted morsellised cancellous bone graft and cement. A 10- to 15-year follow-up of 60 revision arthroplasties.
We report a long-term review of 60 acetabular components revised using impacted, morsellised bone allografts and a cemented polyethylene cup. The acetabular defects were cavitary (37) or combined (23). Follow-up was for a mean 11.8 years (10 to 15). Further revision was needed in five hips, two for septic and three for aseptic loosening. The overall survival rate at 11.8 years was 90%; excludin...
متن کاملAcetabular Reconstruction with the Burch-Schneider Antiprotrusio Cage and Bulk Allografts: Minimum 10-Year Follow-Up Results
Reconstruction of severe pelvic bone loss is a challenging problem in hip revision surgery. Between January 1992 and December 2000, 97 hips with periprosthetic osteolysis underwent acetabular revision using bulk allografts and the Burch-Schneider antiprotrusio cage (APC). Twenty-nine patients (32 implants) died for unrelated causes without additional surgery. Sixty-five hips were available for ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Zeitschrift fur Orthopadie und Unfallchirurgie
دوره 145 Suppl 1 شماره
صفحات -
تاریخ انتشار 2007