Comparison of esophageal placement of Bravo capsule system under direct endoscopic guidance with conventional placement method

نویسندگان

  • Aijaz A Sofi
  • Charles Filipiak
  • Thomas Sodeman
  • Usman Ahmad
  • Ali Nawras
  • Isam Daboul
چکیده

BACKGROUND Conventional placement of a wireless esophageal pH monitoring device in the esophagus requires initial endoscopy to determine the distance to the gastroesophageal junction. Blind placement of the capsule by the Bravo delivery system is followed by repeat endoscopy to confirm placement. Alternatively, the capsule can be placed under direct vision during endoscopy. Currently there are no published data comparing the efficiency of one method over the other. The objective of this study was to compare the method of Bravo wireless pH device placement under direct visualization with the conventional method. METHODS A retrospective study involving 58 patients (29 patients with indirect and 29 patients with direct visualization) who had Bravo capsule placement. The physician endoscopy procedure notes, nurse's notes, postprocedure notes, recovery notes, and pH monitoring results were reviewed. The safety of the procedures, length of the procedures, and patient tolerability were evaluated. RESULTS None of the 58 patients had early detachment of the device and had no immediate procedure-related complications. The overall incidence of complications in both the groups was similar. No failures due to the technique were noted in either group. Average amount of time taken for the procedure was similar in both groups. CONCLUSION The technique of placing a Bravo pH device under direct visualization is as safe and effective as the conventional method. In addition, there is an added advantage of avoiding a second endoscopic intubation in the direct visualization technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Gastroesophageal Reflux Disease Using the Bravo Capsule pH System.

Gastroesophageal reflux disease (GERD) is a disease predominantly seen in the West but there is a rising trend in Asia. Ambulatory 24-hour catheter-based pH monitoring has been the de facto gold standard test for GERD that correlates symptoms with acid reflux episodes. However, drawbacks such as patients' discomfort, and catheter displacement render the test as cumbersome and error-prone. The B...

متن کامل

Palliative esophageal stent placement using endoscopic guidance without fluoroscopy.

AIMS Fluoroscopy is not available in every endoscopic unit. This situation leads to delays in treatment or to transfer of patients to other centres for stent insertion. We assessed safety and effectiveness of expandable esophageal metal stent placement under endoscopic control without fluoroscopy using a thin gastroscope. PATIENTS AND METHODS From October 2002 to June 2004, thirty-three conse...

متن کامل

ایمنی و تأثیر استنت‌گذاری در انسداد بدخیم مری: یک مطالعه آینده‌نگر

Abstract: Background: Palliative procedures in esophageal cancer to restore swallowing are preferable to major surgery in most cases. The aim of this prospective study was to provide further information on treatment techniques, complications, and survival in the patients with malignant esophageal obstruction undergoing endoscopic palliative therapy using Self-Expanding Metal Stents (SEMS). Ma...

متن کامل

Subclavian artery-esophageal fistula after placement of a self-expanding metal stent in a patient with esophagogastric anastomosis stenosis

Background: There have been reports on stent-related vascular erosions about patients with benign or malignant stenosis of the esophagus who received endoscopic stent insertion for palliative intention for oral intake. Case presentation: A 61-year-old woman with esophageal cancer located in the middle part of esophagus was treated with esophagectomy. Two years following the surgery, malignan...

متن کامل

Adaptive fuzzy pole placement for stabilization of non-linear systems

A new approach for pole placement of nonlinear systems using state feedback and fuzzy system is proposed. We use a new online fuzzy training method to identify and to obtain a fuzzy model for the unknown nonlinear system using only the system input and output. Then, we linearized this identified model at each sampling time to have an approximate linear time varying system. In order to stabilize...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2010