Histologic effects of contact ultrasound for the treatment of glaucoma.
نویسندگان
چکیده
The histologic effects of a contact ultrasound applicator were compared with those of the immersion applicator that is currently used clinically for the treatment of glaucoma. The applicator coupling cone uses a distensible rubber membrane that can be inflated to control stand-off distance relative to the surface of the eye. This feature allows the focal point of the therapeutic beam to be placed at selective depths. Histologic comparisons of lesions in rabbit and pig eyes showed lesions in the sclera and ciliary body that were similar to those produced by the immersion transducer when the same focal position was used. Moving the focal point to a greater depth resulted in less superficial damage, yet still produced ciliodestruction. Damage to the blood supply of the ciliary body, as found in human cadaver eyes, may be an additional mechanism of action of therapeutic ultrasound, and perhaps of other transscleral high-energy modalities.
منابع مشابه
Rho Kinase Inhibitors as a Novel Treatment for Glaucoma and Ocular Hypertension
In an elegant example of bench-to-bedside research, a hypothesis that cells in the outflow pathway actively regulate conventional outflow resistance was proposed in the 1990s and systematically pursued, exposing novel cellular and molecular mechanisms of intraocular pressure (IOP) regulation. The critical discovery that pharmacologic manipulation of the cytoskeleton of outflow pathway cells dec...
متن کاملStem Cells in Glaucoma Management
Glaucoma is the leading cause of preventable blindness worldwide. Despite tremendous advances in medical and surgical management of glaucoma in the recent years, the prevalence of glaucoma related blindness is anticipated to increase in the future decades because of the aging population. Stem cells have the potential to change the glaucoma management in several ways. There are several areas of ...
متن کاملComparison the treatment effects between simultaneous dual frequency and single frequency irradiation of ultrasound in a murine model of breast adenocarcinoma
Introduction: Transient cavitations induced by low frequency irradiation of ultrasound can be used to treat tumors. Previous studies in in-vitro experiments have shown that induced cavitation by dual or multiple frequencies of ultrasound is greater than induced cavitation by single frequency irradiation. In this study, we compared and evaluated the treatment effects of dual frequency irradiatio...
متن کاملTherapeutic effects of high intensity focused ultrasound for in patients with benign uterine tumors with regard to lifestyle and obstetric characteristics
Background: The present investigation compared the decrease in the volume of benign tumor before and after High Intensity Focused Ultrasound (HIFU) treatment to evaluate the therapeutic effects of HIFU. in terms of Lifestyle and obstetric characteristics of in patients with Benign Uterine Tumors. Materials and Methods: To collect the data on each patients’ lifestyle and obstetric characteristic...
متن کاملتأثیر امواج فراصوت بر باززایی ساقههای چندگانه از نوک ساقه اسپرس (Onobrychis sativa)
Ultrasound has multiple industrial, medical and biotechnological applications. Ultrasound increases membrane permeability and causes several biological effects in plant cells. In this research, the effects of ultrasound on survival and growth of the sainfoin shoot apex explants were investigated. For this, shoot apex explants were exposed to ultrasonic waves (Frequency 37 kHz) for 0, 20, 30, 40...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 32 7 شماره
صفحات -
تاریخ انتشار 1991