Elastic Tube Model of the Aorta
نویسندگان
چکیده
The purpose of this study was to determine the influence of radial motion of an arterial wall on the shear stress that flowing blood imposes on the wall (wall shear stress). Wall shear stress is known to influence endothelial cell function and may play a role in atherogenesis, but its magnitude and distribution in the circulation are not well understood. To simulate arterial wall motion, we used both straight and curved rubber tubing models in a mock circulatory system incorporating a variable impedance element distal to the model aorta. Wall shear rate was measured with a hot-film anemometer probe mounted flush on the tubing wall and free to move with the wall. Wall shear stress was determined as the product of wall shear rate and viscosity. By changing the distal impedance element, we determined the influence of the (temporal) phase angle between pressure and flow, or equivalently, tube diameter and flow, on wall shear stress. We observed a fivefold increase in peak wall shear stress and the onset of intense wall shear stress reversal in sinusoidal flows as the phase angle between pressure and flow was reduced from -60° to -80°. Wall shear stresses were insensitive to this same phase angle when its value
منابع مشابه
Histological Study of the Elastic Artery, Muscular Artery, and Their Junction in Neonate Dog
Introduction: We did this study because there were a few studies about aorto-branch junction. Methods: Four light microscope and electron microscope study, the abdominal aorta, renal artery, and the adjoining right and left renal arteries were dissected out from 4 neonate dogs. Results: Based on the results, there is only one cell type in the tunica intima of endothelium in both art...
متن کاملStudy of Pulsatile Non-Newtonian Blood Flow Through Abdominal Aorta and Renal Arteries Incorporating Fluid- Structure Interaction
Background: The interaction between the blood and the vessel wall is of great clinical interest in studying cardiovascular diseases, the major causes of death in developed countries.Objective: To understand the effects of incorporating fluid-structure interaction into the simulation of blood flow through an anatomically realistic model of abdominal aorta and renal arteries reconstructed from CT...
متن کاملNonlinear Vibration of Smart Micro-Tube Conveying Fluid Under Electro-Thermal Fields
In this study, electro-thermo-mechanical nonlinear vibration and instability of embedded piezoelectric micro-tube is carried out based on nonlocal theory and nonlinear Donnell's shell model. The smart micro-tube made of Poly-vinylidene fluoride (PVDF) is conveying an isentropic, incompressible fluid. The detailed parametric study is conducted, focusing on the remarkable effects of mean flow vel...
متن کاملWave Propagation Analysis of CNT Reinforced Composite Micro-Tube Conveying Viscose Fluid in Visco-Pasternak Foundation Under 2D Multi-Physical Fields
In this research, wave propagation analysis in polymeric smart nanocomposite micro-tubes reinforced by single-walled carbon nanotubes (SWCNT) conveying fluid is studied. The surrounded elastic medium is simulated by visco-Pasternak model while the composite micro-tube undergoes electro-magneto-mechanical fields. By means of micromechanics method, the constitutive structural coefficients of nano...
متن کاملAortic Pseudo aneurysm 3 Years after Interposition Tube Graft for Acute Dissection of Ascending Aorta
Introduction: Patients with primary acute aortic dissection are at higher risk of complications, including increasing aortic aneurysm diameter, aortic rupture, aortic pseudo aneurysm, and recurrent aortic dissection. Case presentation We presented the case of a recurrent pseudo aneurysm and rupture of the aorta in the distal a...
متن کاملStructure of the orifice of the renal artery in the abdominal aorta in adult male dog
One of the locations of renal artery atherosclerosis is at the orifice of the renal artery, therefore thestructure of this orifice was assessed in 6 normal, adult male dogs by light microscopy (LM) andtransmission electron microscopy (TEM). For the LM study, processed tissues were embedded in paraffinand sectioned serially into 6-μm thickness. Sections were stained with orcein. For the TEM stud...
متن کامل