A computed tomography phantom study of foam earplugs

نویسندگان

  • Li-Sheng Hsu
  • Ju-Bei Yen
  • Shie-Shan Wang
  • Chien-Lin Liao
چکیده

Ingestion of a foreign body is common among children. However, ingestion of foam earplugs (FEPs) has not been reported previously. A 7-month-old female infant presented with small bowel obstruction, which was finally proved to be a case of FEP ingestion.Computed tomography (CT) phantom study was performed to examine the imaging features of FEPs. We studied the following dry and fully wet FEPs, FEPs squeezed in pure water to varying degrees, and FEPs with different degrees of compression in the dry and wet states from day 0 to 6 and all scanned with a CT scanner.The density of a dry FEP is -843.5 ± 4.5 Hounsfield units (HU) and it increases to 0.76 ± 9.3 HU when fully wet. The densities of FEPs ranged from -844.2 to 1.0 HU with different water/air ratios, and some showed a heterogeneous geographic pattern. The densities of FEPs increase due to compression and gradual water absorption.FEPs can be potentially hazardous objects to children. Owing to the special foam structure of the FEP, it can mimic a fatty lesion if the density ranges from -100 to -50 HU; moreover, it can hide in the water if fully wet. However, it should not be mistaken as air, as the density of a dry FEP is -843.5 HU, and the contour can be observed if the window level is set appropriately. Because of its soft texture, the surgeon should be careful not to miss an FEP during the operation. Moreover, radiologists should be familiar with the CT features of FEPs so that they can be identified before surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of a Liver Phantom Based on Computed Tomography Images for Dosimetric Purpose

Introduction: The present study was conducted with the aim of designing a liver phantom for dosimetry. To benchmark the results obtained by the developed liver phantom, another method was applied for the dosimetry of a real liver tissue using imaging. Materials and Methods: For the purpose of the study, a real liver tissue was converted into a phantom based on thegram-molecular weight of the co...

متن کامل

Effect of Phantom Size and Tube Voltage on the Size-Conversion Factor for Patient Dose Estimation in Computed Tomography Examinations

Introduction: This study aimed to establish the conversion factors to normalize the output dose of volumetric computed tomography dose index (CTDIvol) to the patient dose (i.e. size-specific dose estimate (SSDE)) for various phantom diameters and tube voltages. Material and Methods: In-house cylindrical acrylic phantoms with physical diameter...

متن کامل

Design and Construction of an Affordable Phantom for Electron Density Measurement and Linearity Tests of Computed Tomography Systems

Introduction: The performance of computed tomography is routinely checked using phantoms, which are known as important diagnostic imaging tools. Depending upon the aim of the study, different phantoms are designed, while trying to satisfy certain levels of diversities in their application. Material and Methods: The present study describes the...

متن کامل

Correlation Between Tissue Densities in Computed Tomography and Three Different Cone-Beam Computed Tomography Units (In Vitro)

Background and Aim: Bone density is of great assistance in the selection of the proper implant site. The present study aimed to assess the correlation between tissue densities in computed tomography (CT) and three different cone-beam computed tomography (CBCT) units. Materials and Methods: In this descriptive study, a radiographic phantom consisting of a transparent polymethyl methacrylate (PM...

متن کامل

Thorax organ dose estimation in computed tomography based on patient CT data using Monte Carlo simulation

Background:  This study presents patient specific and organ dose estimation in computed tomography (CT) imaging of thorax directly from patient CT image using Monte Carlo simulation.  Patient's CT image is considered as the patient specific phantom and the best representative of patient physical index in order to calculate specific organ dose. Materials and Methods: EGSnrc /BEAMnr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 95  شماره 

صفحات  -

تاریخ انتشار 2016