A computed tomography phantom study of foam earplugs
نویسندگان
چکیده
Ingestion of a foreign body is common among children. However, ingestion of foam earplugs (FEPs) has not been reported previously. A 7-month-old female infant presented with small bowel obstruction, which was finally proved to be a case of FEP ingestion.Computed tomography (CT) phantom study was performed to examine the imaging features of FEPs. We studied the following dry and fully wet FEPs, FEPs squeezed in pure water to varying degrees, and FEPs with different degrees of compression in the dry and wet states from day 0 to 6 and all scanned with a CT scanner.The density of a dry FEP is -843.5 ± 4.5 Hounsfield units (HU) and it increases to 0.76 ± 9.3 HU when fully wet. The densities of FEPs ranged from -844.2 to 1.0 HU with different water/air ratios, and some showed a heterogeneous geographic pattern. The densities of FEPs increase due to compression and gradual water absorption.FEPs can be potentially hazardous objects to children. Owing to the special foam structure of the FEP, it can mimic a fatty lesion if the density ranges from -100 to -50 HU; moreover, it can hide in the water if fully wet. However, it should not be mistaken as air, as the density of a dry FEP is -843.5 HU, and the contour can be observed if the window level is set appropriately. Because of its soft texture, the surgeon should be careful not to miss an FEP during the operation. Moreover, radiologists should be familiar with the CT features of FEPs so that they can be identified before surgery.
منابع مشابه
Development of a Liver Phantom Based on Computed Tomography Images for Dosimetric Purpose
Introduction: The present study was conducted with the aim of designing a liver phantom for dosimetry. To benchmark the results obtained by the developed liver phantom, another method was applied for the dosimetry of a real liver tissue using imaging. Materials and Methods: For the purpose of the study, a real liver tissue was converted into a phantom based on thegram-molecular weight of the co...
متن کاملEffect of Phantom Size and Tube Voltage on the Size-Conversion Factor for Patient Dose Estimation in Computed Tomography Examinations
Introduction: This study aimed to establish the conversion factors to normalize the output dose of volumetric computed tomography dose index (CTDIvol) to the patient dose (i.e. size-specific dose estimate (SSDE)) for various phantom diameters and tube voltages. Material and Methods: In-house cylindrical acrylic phantoms with physical diameter...
متن کاملDesign and Construction of an Affordable Phantom for Electron Density Measurement and Linearity Tests of Computed Tomography Systems
Introduction: The performance of computed tomography is routinely checked using phantoms, which are known as important diagnostic imaging tools. Depending upon the aim of the study, different phantoms are designed, while trying to satisfy certain levels of diversities in their application. Material and Methods: The present study describes the...
متن کاملCorrelation Between Tissue Densities in Computed Tomography and Three Different Cone-Beam Computed Tomography Units (In Vitro)
Background and Aim: Bone density is of great assistance in the selection of the proper implant site. The present study aimed to assess the correlation between tissue densities in computed tomography (CT) and three different cone-beam computed tomography (CBCT) units. Materials and Methods: In this descriptive study, a radiographic phantom consisting of a transparent polymethyl methacrylate (PM...
متن کاملThorax organ dose estimation in computed tomography based on patient CT data using Monte Carlo simulation
Background: This study presents patient specific and organ dose estimation in computed tomography (CT) imaging of thorax directly from patient CT image using Monte Carlo simulation. Patient's CT image is considered as the patient specific phantom and the best representative of patient physical index in order to calculate specific organ dose. Materials and Methods: EGSnrc /BEAMnr...