Role of (99m)tc-hexakis-2-methoxy-isobutylisonitrile in the diagnosis and staging of lung cancer.
نویسندگان
چکیده
BACKGROUND Preliminary studies have shown that (99m)Tc-hexakis-2-methoxyisobutylisonitrile (MIBI) is an interesting tracer for various tumors. The aim of this study was to determine the feasibility of using (99m)Tc-MIBI as a diagnostic and staging procedure for lung cancer. METHODS We prospectively compared the results of biopsy with (99m)Tc-MIBI imaging in patients with potentially resectable lung lesions (stages IIIA or lower). In the patients with radiopharmaceutical uptake, the staging provided by CT was compared with that obtained with (99m)Tc-MIBI. RESULTS Ninety-nine of the 116 patients examined had lung cancer. For the diagnosis of malignancy, the specificity of (99m)Tc-MIBI was 100%, sensitivity was 89.8%, positive predictive value was 100%, negative predictive value was 62.9%, and accuracy was 91.4%. In the 87 patients with radiopharmaceutical uptake in their lung cancer, the values for the specificity and sensitivity of (99m)Tc-MIBI in the detection of mediastinal lymph node metastases were 100% and 54.5%, respectively. The corresponding values for CT in the same patients were 87.6% and 63.3%, respectively. The difference in specificity is statistically significant (p = 0.011). CONCLUSIONS This study demonstrates that (99m)Tc-MIBI provides significant diagnostic and staging information in patients with lung lesions. The high specificity and positive predictive value of (99m)Tc-MIBI suggest that this radiopharmaceutical could be a very useful tool for the diagnosis of lung cancer, especially in consideration of its low costs and wide availability.
منابع مشابه
Multiple myeloma in a patient with suspected hyperparathyroidism
Multiple myeloma (MM) is a clonal B-lymphocyte neoplasm of terminally differentiated plasma cells. Imaging modalities which allow the recognition of the effects of myeloma cells on the skeletal system have been utilized for a long time. Herein, we represent a patient with generalized osteoporosis and hypercalcemia, who was referred for parathyroid scan, in whom the widespread bone marrow techne...
متن کاملNon-small cell lung cancer functional imaging: increased hexakis-2-methoxy-isobutyl-isonitrile tumor clearance correlates with resistance to cytotoxic treatment.
Detection of P-glycoprotein and other multidrug resistance protein activity is currently under investigation to identify subgroups of cancer patients with tumors resistant to chemotherapy. Application of a test that reliably evaluates the phenomenon in vivo would not only serve as a predictor for responses to chemotherapy but would also be of use in testing the efficacy of multidrug resistance ...
متن کاملTechnetium-99m hexakis 2-methoxy-2-isobutyl isonitrile and thallium-201 extraction, washout, and retention at varying coronary flow rates in rabbit heart.
Technetium-99m hexakis 2-methoxy-2-isobutyl isonitrile (Tc-MIBI) and thallium-201 extraction, washout, and retention were investigated and compared in 20 isolated, isovolumic, retrograde blood-perfused rabbit hearts at flow rates ranging from 0.5 to 3.5 ml/g wet wt min-1 in the absence of tracer recirculation. Mean Tc-MIBI peak instantaneous extraction was lower (0.55 +/- 0.10, p less than 0.00...
متن کاملComparison of I-131, I-123 Absorbed Dose and Tc-99m in Thyroid Scanning Using MCNP Code in ORNL-MIRD Phantom
Introduction: Thyroid cancer is at the ninth from ten of common malignant cancer. A man has higher risk to get Thyroid cancer that a woman has. This organ is lain near human neck. The use of radioactive I-131, I-123 and Tc-99m for diagnosis of thyroid cancer has a risk where other organs around Thyroid will accept dose of radiation. One of the risks is large dose which is accep...
متن کاملF-18-2-fluoro-2-deoxyglucose positron emission tomography compared to technetium-99m hexakis-2-methoxyisobutyl isonitrile single photon emission chest tomography in the diagnosis of indeterminate lung lesions.
BACKGROUND (18)FDG-PET plays a significant role in diagnosing malignancy of lung lesions but remains an expensive test available at a limited number of sites in Italy. OBJECTIVE We prospectively compare the diagnostic accuracy of (99m)Tc-MIBI- SPECT and (18)FDG-PET in patients with indeterminate lung lesions to demonstrate that (99m)Tc-MIBI-SPECT may be considered as a valid alternative when ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 122 4 شماره
صفحات -
تاریخ انتشار 2002