BACKGROUND AND PURPOSE Transcranial Doppler is a useful ancillary test for brain death confirmation because it is safe, noninvasive, and done at the bedside. Transcranial Doppler confirms brain death by evaluating cerebral circulatory arrest. Case series studies have generally reported good correlations between transcranial Doppler confirmation of cerebral circulatory arrest and clinical confirmation of brain death. The purpose of this study is to evaluate the utility of transcranial Doppler as an ancillary test in brain death confirmation. MATERIALS AND METHODS We conducted a systematic review of the literature and a diagnostic test accuracy meta-analysis to compare the sensitivity and specificity of transcranial Doppler confirmation of cerebral circulatory arrest, by using clinical confirmation of brain death as the criterion standard. RESULTS We identified 22 eligible studies (1671 patients total), dating from 1987 to 2014. Pooled sensitivity and specificity estimates from 12 study protocols that reported data for the calculation of both values were 0.90 (95% CI, 0.87-0.92) and 0.98 (95% CI, 0.96-0.99), respectively. Between-study differences in the diagnostic performance of transcranial Doppler were found for both sensitivity (I(2) = 76%; P < .001) and specificity (I(2) = 74.3%; P < .001). The threshold effect was not significant (Spearman r = -0.173; P = .612). The area under the curve with the corresponding standard error (SE) was 0.964 ± 0.018, while index Q test ± SE was estimated at 0.910 ± 0.028. CONCLUSIONS The results of this meta-analysis suggest that transcranial Doppler is a highly accurate ancillary test for brain death confirmation. However, transcranial Doppler evaluates cerebral circulatory arrest rather than brain stem function, and this limitation needs to be taken into account when interpreting the results of this meta-analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of Pediatric Emergency Care Applied Research Network Rules in Prediction of Clinically Important Head Injuries; A Systematic Review and Meta-Analysis

Objective: the present meta-analysis was designed to determine the value of Pediatric Emergency Care Applied Research Network (PECARN) rule in prediction of clinically important traumatic brain injury (ciTBI).Methods: Extensive search was conducted in the databases of Medline, Embase, Scopus, Web of Sciences, Cinahl up to the end of August 2017. The search records were screened and summarized b...

متن کامل

Diagnostic Accuracy of Transcranial Sonography of the Substantia Nigra in Parkinson’s disease: A Systematic Review and Meta-analysis

A large number of articles have reported substantia nigra hyperechogenicity in Parkinson's disease (PD) and have assessed the diagnostic accuracy of transcranial sonography (TCS); however, the conclusions are discrepant. Consequently, this systematic review and meta-analysis aims to consolidate the available observational studies and provide a comprehensive evaluation of the clinical utility of...

متن کامل

Transcranial doppler sonography diagnostic value for the cerebral flow velocity changes in the interictal phase of classic migraine

Background: An imbalance of the cerebrovascular response during functional activation of the brain has been postulated as a factor in the pathophysiology of migraine. The purpose of this study was to determine the transcranial doppler sonography (TDS) diagnostic value for the cerebral flow velocity changes in the interictal phase of classic migraine. Methods: This study was carried out on 46 pa...

متن کامل

The Effects of Sildenafil on Fetal Doppler Indices: A Systematic Review and Meta-Analysis

 Background & Objective:  Sildenafil citrate is a potential new strategy for the management of intrauterine growth restriction (IUGR) and preeclampsia, although its efficacy still needs to be approved. Accordingly, the aim of this study was to systematically assess the effectiveness of sildenafil on improving fetal Doppler indices, as well as the most common adverse effects of sildenafil.  ...

متن کامل

Transcranial Doppler in brain death assessment. Perspective and implications in the Saudi Arabian health system.

Transcranial Doppler is a non-invasive, non-ionizing ultrasound-based imaging modality that is inexpensive with a short learning curve. It can be performed and interpreted at the bedside. This review explores the value of the transcranial Doppler technique as a confirmatory tool for brain death. The early confirmation of brain death enables the treating physicians in early decision-making and f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 37 3  شماره 

صفحات  -

تاریخ انتشار 2016