Laboratory cryo soft X-ray microscopy.

نویسندگان

  • H M Hertz
  • O von Hofsten
  • M Bertilson
  • U Vogt
  • A Holmberg
  • J Reinspach
  • D Martz
  • M Selin
  • A E Christakou
  • J Jerlström-Hultqvist
  • S Svärd
چکیده

Lens-based water-window X-ray microscopy allows two- and three-dimensional (2D and 3D) imaging of intact unstained cells in their near-native state with unprecedented contrast and resolution. Cryofixation is essential to avoid radiation damage to the sample. Present cryo X-ray microscopes rely on synchrotron radiation sources, thereby limiting the accessibility for a wider community of biologists. In the present paper we demonstrate water-window cryo X-ray microscopy with a laboratory-source-based arrangement. The microscope relies on a λ=2.48-nm liquid-jet high-brightness laser-plasma source, normal-incidence multilayer condenser optics, 30-nm zone-plate optics, and a cryo sample chamber. We demonstrate 2D imaging of test patterns, and intact unstained yeast, protozoan parasites and mammalian cells. Overview 3D information is obtained by stereo imaging while complete 3D microscopy is provided by full tomographic reconstruction. The laboratory microscope image quality approaches that of the synchrotron microscopes, but with longer exposure times. The experimental image quality is analyzed from a numerical wave-propagation model of the imaging system and a path to reach synchrotron-like exposure times in laboratory microscopy is outlined.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Soft X-ray microscopy with a cryo scanning transmission X-ray microscope: I. Instrumentation, imaging and spectroscopy.

We have developed a cryo scanning transmission X-ray microscope which uses soft X-rays from the National Synchrotron Light Source. The system is capable of imaging frozen hydrated specimens with a thickness of up to 10 microm at temperatures of around 100 K. We show images and spectra from frozen hydrated eukaryotic cells, and a demonstration that biological specimens do not suffer mass loss or...

متن کامل

Towards an atlas of mammalian cell ultrastructure by cryo soft X-ray tomography.

We provide a catalog of 3D cryo soft X-ray tomography (cryo-SXT) images obtained from ∼6 to 12μm thick mouse adenocarcinoma cells. Included are multiple representative images of nuclei, nucleoli, nuclear membrane, nuclear membrane channels, mitochondria, lysosomes, endoplasmic reticulum, filaments and plasma membrane, plus three structures not previously described by cryo-SXT, namely Golgi, mic...

متن کامل

مکانیسم تولید و ویژگی‌های تابش چرنکوف در ناحیه اشعه ایکس نرم

In this paper, the production mechanisms and the spectral-angular distribution of X-ray Cherenkov radiation (XCR) was investigated in detail and some unique properties of XCR and its applications were discussed. It is shown that, in the vicinity of the atomic absorption edges, the real and the imaginary parts of the refractive index are varied drastically and for some materials the refractive i...

متن کامل

Multimodal nanoparticles as alignment and correlation markers in fluorescence/soft X-ray cryo-microscopy/tomography of nucleoplasmic reticulum and apoptosis in mammalian cells

Correlative fluorescence and soft X-ray cryo-microscopy/tomography on flat sample holders is perfectly suited to study the uncompromised physiological status of adherent cells at its best possible preservation by imaging after fast cryo-immobilization. To understand the mechanism by which herpesviruses induce nucleoplasmic reticulum, i.e. invaginations of the nuclear envelope, during their egre...

متن کامل

High-resolution computed tomography with a compact soft x-ray microscope.

Computed tomography based on high-resolution soft x-ray microscopy utilizes the natural contrast for biological specimens provided by the water window (lambda = 2.4 - 4.4 nm) and the high resolving power of zone plate objectives. It is capable of revealing the 3D structure of biological specimens at sub-visible-microscopic resolution. To date, the technique has only been available at synchrotro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of structural biology

دوره 177 2  شماره 

صفحات  -