Simultaneous quantitation of alpha-ketoglutaric acid and 5-hydroxymethylfurfural in plasma by HPLC with UV and fluorescence detection.

نویسندگان

  • Fabrizio Donnarumma
  • Reinhold Wintersteiger
  • Margot Schober
  • Joachim Greilberger
  • Veronika Matzi
  • Alfred Maier
  • Michaela Schwarz
  • Astrid Ortner
چکیده

Alpha-ketoglutaric acid (KG) and hydroxymethylfurfural (HMF) are currently being investigated in clinical trials as an approach in targeted cancer therapy. Hence, a method for the simultaneous determination of KG and HMF in plasma has been developed. Due to the strongly discriminative chemical properties of KG and HMF, SPE purification is performed using an ion-exchange cartridge to separate KG, and a hydrophobic polymeric cartridge to separate HMF. The cartridges are connected together for several steps, thus resulting in a quicker approach for the purification of plasma samples. The derivatization step is based on the reaction of the carbonyl groups of KG and HMF with dansylhydrazine (DNSH) catalyzed by trifluoroacetic acid. The formed derivatives could be separated by reversed-phase LC on a C8-column, and analyzed by UV and fluorescence detection in a single run using a gradient program. The obtained results show good reproducibility, specificity, and detection limits down to the low picomole range.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simple and sensitive high performance liquid chromatographic method for the simultaneous quantitation of the phenylalanine in human plasma

Phenylalanine (Phe) is the most reliable indicator for the diagnosis of phenylketonuria (PKU). The purpose of this study is to establish a reliable and quick method for the assignment of Phe in peripheral capillary blood from newborns and children by high performance liquid chromatography with ultraviolet detection (HPLC-UV). PKU is an inborn error of metabolism characterized by the inability o...

متن کامل

A Simple and Sensitive HPLC Method for Fluorescence Quantitation of Doxorubicin in Micro-volume Plasma: Applications to Pharmacokinetic Studies in Rats

A validated HPLC method was developed to determine doxorubicin concentration in a small volume of rat plasma (60 µl) with convenient fluorescence detection. Sample preparation includes a simple one-step liquid-liquid extraction using minimum amount of organic solvent, with extraction recoveries more than 95%. The analysis was accomplished using PerfectSil C18 column maintained at 35 °C and a mo...

متن کامل

A Simple and Sensitive HPLC Method for Fluorescence Quantitation of Doxorubicin in Micro-volume Plasma: Applications to Pharmacokinetic Studies in Rats

A validated HPLC method was developed to determine doxorubicin concentration in a small volume of rat plasma (60 µl) with convenient fluorescence detection. Sample preparation includes a simple one-step liquid-liquid extraction using minimum amount of organic solvent, with extraction recoveries more than 95%. The analysis was accomplished using PerfectSil C18 column maintained at 35 °C and a mo...

متن کامل

High Performance Liquid Chromatographic Estimation of Drotaverine Hydrochloride and Mefenamic Acid in Human Plasma

The present work describes a reverse phase HPLC method for the quantitation of drotaverine hydrochloride and mefenamic acid in human plasma. Organic solvent system used for liquid extraction composed of dichloromethane, and isopropyl alcohol in the ratio 80:20 (v/v). The compounds were separated on a Thermo BDS Hypersil C8 (25.0 cm×4.6 mm, 5 µm particle size) column in isocratic mode with a mix...

متن کامل

High Performance Liquid Chromatographic Estimation of Drotaverine Hydrochloride and Mefenamic Acid in Human Plasma

The present work describes a reverse phase HPLC method for the quantitation of drotaverine hydrochloride and mefenamic acid in human plasma. Organic solvent system used for liquid extraction composed of dichloromethane, and isopropyl alcohol in the ratio 80:20 (v/v). The compounds were separated on a Thermo BDS Hypersil C8 (25.0 cm×4.6 mm, 5 µm particle size) column in isocratic mode with a mix...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 29 12  شماره 

صفحات  -

تاریخ انتشار 2013