Modification of Commercial Force Feedback Hardware for Needle Insertion Simulation
نویسندگان
چکیده
A SensAble Omni force feedback device has been modified to increase the face validity of a needle insertion simulation. The new end effector uses a real needle hub and shortened needle shaft in place of the Omni's pre-fitted pen shaped end effector. This modification facilitates correct procedural training through the simulation of co-located visual and haptic cues in an augmented reality approach to simulation. The development of the new end effector is described and a pictorial guide to its manufacture and the fitting process is provided. Initial results from face validation studies bode well for the fidelity of this low cost device.
منابع مشابه
Effects of Rotational Motion in Robotic Needle Insertion
Background: Robotic needle insertion in biological tissues has been known as one the most applicable procedures in sampling, robotic injection and different medical therapies and operations.Objective: In this paper, we would like to investigate the effects of angular velocity in soft tissue insertion procedure by considering force-displacement diagram. Non-homogenous camel liver can be exploite...
متن کاملThe Effect of Visual and Haptic Feedback on Manual and Teleoperated Needle Insertion
In this paper, we present a study that evaluates the effect of visual and haptic feedbacks and their relevance to human performance in a needle insertion task. A virtual needle insertion simulator with a four-layer tissue model (skin, fat, muscle, and bone) and haptic feedback is used for perceptual experiments. The task was to detect the puncture of a particular layer using haptic and visual c...
متن کاملThe Biomechanics of Percutaneous Needle Insertion
Emphasis has been placed on improving patient outcomes in healthcare management. Significant patient morbidity and mortality exists from inappropriate procedural technique and percutaneous catheter needle insertion procedures have been linked to medical complications. Healthcare trainees learn these procedures through trial and error and most existing simulators are synthetic tissue based and l...
متن کاملForce feedback for a spine biopsy simulator with volume graphic model
This paper shows how to implement haptic rendering for a needle insertion problem with volume graphic model. The target is a spine biopsy simulator for tumor inspection by needle insertion. Simulated force is calculated from the relationship between voxel data and the orientation and position of the needle. At first, it is generated using PHANToM. The needle puncturing resistive force is calcul...
متن کامل3D Haptic Needle Insertion Simulator Utilising An Agent Based Spherical Voxel Model
This paper describes a technique for the real-time modeling of deformable tissue. Specifically geared towards needle insertion simulation, the low computational requirements of the model enable highly accurate haptic feedback to a user without introducing noticeable time delay or buzzing generally associated with haptic surgery simulation. Using a spherical voxel array combined with aspects of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Studies in health technology and informatics
دوره 163 شماره
صفحات -
تاریخ انتشار 2011