STUDY OBJECTIVES To compare in a multicenter prospective study the efficacy and cost of conventional nasal continuous positive airway pressure (nCPAP) initiated at the sleep laboratory versus auto-nCPAP initiated at home. DESIGN Patients with severe obstructive sleep apnea syndrome (OSAS) were randomized to treatment with either the REM+ auto device in constant mode at the effective pressure determined by titration at the sleep laboratory (n=17) or the REM+ auto device in automatic mode initiated at the patients home by a nurse (n=18). After 2 months, the efficacy and cost of nCPAP therapy and the time from diagnosis to nCPAP were evaluated. All values are reported as means +/- SD. PATIENTS Thirty-five subjects with newly diagnosed OSAS (8 women and 27 men, mean age: 54.3 +/- 10.6 years, apnea-hypopnea index (AHI) 58.1 +/- 14.0 h(-1)). INTERVENTIONS N/A. MEASUREMENTS AND RESULTS Both treatments were used properly and induced similar decreases in the AHI (7.6 +/- 6.9 vs. 10.4 +/ -12.5 h(-1) for auto-nCPAP and conventional nCPAP, respectively; NS) and Epworth Sleepiness score (from 15.5 +/- 4.7 to 7.5 +/- 3.4 vs. 14.7 +/- 3.9 to 7.6 +/- 3.4 for auto-nCPAP and conventional nCPAP, respectively; NS). With auto-nCPAP initiated at home, the time from diagnosis to final adjustment of nCPAP was shorter (16.3 +/- 5.0 vs. 47.2 +/- 46.5 days with conventional nCPAP, P < 0.02) and the cost was lower (1,263 +/- 352 vs. 1720+/-455 E, respectively; P < 0.05). CONCLUSIONS Treatment of OSAS with auto-nCPAP initiated at home is effective and reliable and reduces the time from diagnosis to therapy and the cost of treatment.
منابع مشابه
CPAP titration by an auto-CPAP device based on snoring detection: a clinical trial and economic considerations.
This study aimed to assess the ability of an auto-nasal continuous positive airway pressure (nCPAP) device (REM + auto; NPBFD, Nancy, France) to predict the optimal constant nCPAP level. The apnoea/hypopnoea detection facility of the auto-nCPAP device was deliberately disabled and nasal mask pressure vibration detection was the only mode of pressure setting. The auto-nCPAP device was tested on ...
متن کاملThe use of nasal continuous positive airway pressure to treat obstructive sleep apnoea.
AIM To review 66 children with obstructive sleep apnoea (OSA) for whom a trial of nasal continuous positive airway pressure (nCPAP) was proposed. METHODS Baseline sleep studies were performed to assess OSA severity; a trial of nCPAP was performed where moderate to severe OSA, not relieved by adenotonsillectomy, was found. The nCPAP trial was considered either technically successful (ST), if t...
متن کاملHeated Humidified High-Flow Nasal Cannula Versus Nasal Continuous Positive Airway Pressure for the Facilitation of Extubation in Preterm Neonates with Respiratory Distress
Background: Heated humidified high-flow nasal cannula (HHHFNC) is gaining popularity as an alternative to nasal continuous positive airway pressure (nCPAP) therapy in the management of preterm neonates with respiratory distress due to ease of administration and patient comfort. However, limited evidence is available addressing its risks and benefits. To study the efficacy and safety of HHHFNC i...
متن کاملEvaluation of an auto-nCPAP device based on snoring detection.
We evaluated an auto-nasal continuous positive airway pressure (nCPAP) prototype (MC+; SEFAM, Nancy, France) in which apnoea/hypopnoea detection was disabled and nasal mask pressure vibration detection was the only mode of pressure setting. The device was tested in 15 previously untreated obstructive sleep apnoea patients during a night with polysomnography. We observed that a single night of a...
متن کاملHeated, humidified high-flow nasal cannula versus nasal CPAP for respiratory support in neonates.
BACKGROUND AND OBJECTIVE Heated, humidified high-flow nasal cannula (HHHFNC) is commonly used as a noninvasive mode of respiratory support in the NICU. The safety and efficacy of HHHFNC have not been compared with other modes of noninvasive support in large randomized trials. The objective was to assess the efficacy and safety of HHHFNC compared with nasal continuous positive airway pressure (n...