Coronary artery bypass grafts: ECG-gated multi-detector row CT angiography--influence of image reconstruction interval on graft visibility.

نویسندگان

  • Jürgen K Willmann
  • Dominik Weishaupt
  • Richard Kobza
  • Francis R Verdun
  • Burkhardt Seifert
  • Borut Marincek
  • Thomas Boehm
چکیده

PURPOSE To evaluate the influence of different reconstruction intervals of retrospectively electrocardiographically (ECG)-gated multi-detector row computed tomographic (CT) angiography on image quality of different segments of various types of coronary artery bypass grafts. MATERIALS AND METHODS Twenty consecutive patients with 62 grafts underwent retrospectively ECG-gated four-channel multi-detector row CT angiography and conventional coronary angiography. Raw helical CT data were reconstructed at 0%-90% of the cardiac cycle in increments of 10%. Each graft was separated into three segments (proximal segment, graft body, and distal anastomosis). Three graft types were identified according to site of distal anastomosis. Two readers assessed image quality of segments and graft types. Effective radiation dose was calculated. RESULTS Best image quality of all segments was obtained at a reconstruction interval of 50%-70% of the cardiac cycle. Image quality of the proximal segment did not vary significantly with different reconstruction intervals (analysis of variance, P =.8), whereas image quality of the graft body and distal anastomosis changed significantly with varying reconstruction intervals (P <.001). Distal anastomosis and body of types 1 and 2 grafts were best seen at 60%-70% of the cardiac cycle, whereas distal anastomosis and body of type 3 grafts were best visualized at 50%. Accuracy of CT angiography for detection of graft patency was 94% for reader 1 and 95% for reader 2. Effective dose for CT was 11.4 mSv for both men and women. Mean effective dose for angiography was 2.1 mSv for men and women. CONCLUSION Optimal selection of reconstruction interval improves image quality of the graft body and of distal anastomosis in particular.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ECG-gated reconstructed multi-detector row CT coronary angiography: effect of varying trigger delay on image quality.

PURPOSE To evaluate the effectiveness of electrocardiographically (ECG)-gated retrospective image reconstruction for multi-detector row computed tomographic (CT) coronary angiography in reducing cardiac motion artifacts and to evaluate the influence of heart rate on cardiac image quality. MATERIALS AND METHODS Sixty-five patients with different heart rates underwent coronary CT angiography. R...

متن کامل

Noninvasive postoperative angiography for internal mammary artery grafts.

Recently, noninvasive imaging modalities such as electron-beam computed tomography, magnetic resonance angiography, and single-slice helical computed tomography (CT) have emerged as ways to visualize the coronary arteries. With regard to internal mammary artery grafts, however, conventional 3D imaging techniques have failed to demonstrate consistently satisfactory performance. We overcame these...

متن کامل

Noninvasive visualization of coronary artery bypass grafts using 16-detector row computed tomography.

OBJECTIVES The aim of this study was to evaluate the diagnostic accuracy of a 16-detector row computed tomography (CT) scanner for the assessment of coronary artery bypass grafts. BACKGROUND A new generation of multislice spiral CT scanners, equipped with more and thinner detector rows, allows for reliable noninvasive detection of obstructive coronary artery disease. METHODS The study inclu...

متن کامل

Prospectively versus Retrospectively ECG-Gated 256-Slice CT Angiography to Assess Coronary Artery Bypass Grafts — Comparison of Image Quality and Radiation Dose

OBJECTIVE In this retrospective non-randomized cohort study, the image quality and radiation dose were compared between prospectively electrocardiogram (ECG)-gated axial (PGA) and retrospectively ECG-gated helical (RGH) techniques for the assessment of coronary artery bypass grafts using 256-slice CT. METHODS We studied 124 grafts with 577 segments in 64 patients with a heart rate (HR) <85 bp...

متن کامل

A pictorial review of coronary artery bypass grafts at multidetector row CT.

Multidetector row CT scanners with submillimeter spatial resolution and high temporal resolution are now available and are increasingly used for noninvasive assessment of vascular disease including coronary arteries and grafts. The entire heart and graft course can be scanned within a single breath-hold, and contrast-enhanced images are reconstructed through retrospective ECG gating. In this pi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Radiology

دوره 232 2  شماره 

صفحات  -

تاریخ انتشار 2004