Computer-assisted trajectory planning for percutaneous needle insertions.
نویسندگان
چکیده
PURPOSE Computed tomography (CT) guided minimally invasive interventions such as biopsies or ablation therapies often involve insertion of a needle-shaped instrument into the target organ (e.g., the liver). Today, these interventions still require manual planning of a suitable trajectory to the target (e.g., the tumor) based on the slice data provided by the imaging modality. However, taking into account the critical structures and other parameters crucial to the success of the intervention--such as instrument shape and penetration angle--is challenging and requires a lot of experience. METHODS To overcome these problems, we present a system for the automatic or semiautomatic planning of optimal trajectories to a target, based on 3D reconstructions of all relevant structures. The system determines possible insertion zones based on so-called hard constraints and rates the quality of these zones by so-called soft constraints. The concept of pareto optimality is utilized to allow for a weight-independent proposal of insertion trajectories. In order to demonstrate the benefits of our method, automatic trajectory planning was applied retrospectively to n = 10 data sets from interventions in which complications occurred. RESULTS The efficient (graphics processing unit-based) implementation of the constraints results in a mean overall planning time of about 9 s. The examined trajectories, originally chosen by the physician, have been rated as follows: in six cases, the insertion point was labeled invalid by the planning system. For two cases, the system would have proposed points with a better rating according to the soft constraints. For the remaining two cases the system would have indicated poor rating with respect to one of the soft constraints. The paths proposed by our system were rated feasible and qualitatively good by experienced interventional radiologists. CONCLUSIONS The proposed computer-assisted trajectory planning system is able to detect unsafe and propose safe insertion trajectories and may especially be helpful for interventional radiologist at the beginning or during their interventional training.
منابع مشابه
Robotic Guidance of Flexible Needle for Percutaneous Therapy
Flexible needle insertion for percutaneous therapies is formulated in this paper as a trajectory planning problem of a linear beam, supported by virtual springs. Using this simplified model, the forward and inverse kinematics of the needle is solved analytically, providing a way for simulation and path planning in real-time. Using the inverse kinematics, the required needle basis trajectory can...
متن کاملTrajectory optimization for the planning of percutaneous radiofrequency ablation of hepatic tumors.
Radiofrequency ablation is increasingly used in the treatment of hepatic tumors. Planning the percutaneous intervention is essential and particularly difficult. In this paper, we focus on an automated computation of optimal needle insertion in computer-assisted surgery with 3D visualization. First, we review our method which delineates on the skin of a virtual patient the candidate zones for ne...
متن کاملFlexible Needle Steering and Optimal Trajectory Planning for Percutaneous Therapies
Flexible needle insertion into viscoelastic tissue is modeled in this paper with a linear beam supported by virtual springs. Using this simplified model, the forward and inverse kinematics of the needle is solved analytically, providing a way for simulation and path planning in real-time. Using the inverse kinematics, the required needle basis trajectory can be computed for any desired needle t...
متن کاملMulti-criteria Trajectory Planning for Hepatic Radiofrequency Ablation
In this paper, we propose a method based on multiple criteria to assist physicians in planning percutaneous RFA on liver. We explain how we extracted information from literature and interviews with radiologists, and formalized them into geometric constraints. We expose then our method to compute the most suitable needle insertion in two steps: computation of authorized insertion zones and multi...
متن کاملPreoperative trajectory planning for percutaneous procedures in deformable environments
In image-guided percutaneous interventions, a precise planning of the needle path is a key factor to a successful intervention. In this paper we propose a novel method for computing a patient-specific optimal path for such interventions, accounting for both the deformation of the needle and soft tissues due to the insertion of the needle in the body. To achieve this objective, we propose an opt...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 38 6 شماره
صفحات -
تاریخ انتشار 2011