Non-separation assay for glycohemoglobin.
نویسندگان
چکیده
The determination of glycohemoglobin [HbA1c, HbA1, or total glycohemoglobin (GHb)] has become an established procedure in the management of diabetes mellitus. Here, we describe the development of a simple, fluorescence, non-separation assay for the percentage of GHb (%GHb). The fluorescence of an eosin-boronic acid derivative when it was mixed with hemolysates of unwashed erythrocytes was quenched in proportion to the percentage of glycohemoglobin. Measurement of the fluorescence intensity gave an estimate of GHb in the sample, and measurement of light absorbance gave an estimate of total hemoglobin. A combination of the two measurements gave the assay response. Comparison with HPLC (Menarini-Arkray HA-8140 fully automated analyzer) for the percentage of HbA1 (%HbA1) gave %GHb(NETRIA) = 1.1(SD +/-0.03)%HbA1 +0.6(SD +/-0.3), S(y/x) = 0.821, r = 0.972, n = 80; comparison for HbA1c gave %GHb(NETRIA) = 1.3(SD +/-0.04)%HbA1c + 1.8(SD +/-0.3), S(y/x) = 0.813, r = 0.973, n = 80. Precision, estimated as the percentage of the CV of the %GHb assay results, was <2% (intraassay, range 5-22% GHb) and <4.2% (interassay, range 4-16% GHb). Dilution of a high-percentage GHb sample lysate showed that the assay was linear, and addition of glucose (60 mmol/L), bilirubin (250 micromol/L), and triglycerides (14 mmol/L) to low, medium, and high %GHb samples showed no clinical interference in assay results.
منابع مشابه
Fully automated assay of glycohemoglobin with the Abbott IMx analyzer: novel approaches for separation and detection.
We describe a novel assay for measuring glycohemoglobin directly from anticoagulated whole blood with the Abbott IMx analyzer. The glycohemoglobin is labeled with a soluble polyanionic affinity reagent and the anionic complex is then captured with a cationic solid-phase matrix. Glycohemoglobin is quantified by measuring the quenching by heme of the static fluorescence from an added fluorophore....
متن کاملIncreased fetal hemoglobin in insulin-treated diabetes mellitus contributes to the imprecision of glycohemoglobin measurements.
An increased prevalence of fetal hemoglobin (HbF) has been described in pediatric insulin-dependent patients. The popular electroendosmotic method for glycohemoglobin includes HbF. In an adult population comprising 50 insulin-treated and 57 non-insulin-treated diabetic patients and 57 control subjects, we measured HbF by HPLC and measured glycohemoglobin by both HPLC and an electroendosmotic me...
متن کاملChronic lymphocytic leukemia cells may interfere in a glycated hemoglobin assay based on fluorescence quenching.
Recently, we observed falsely low results by the Abbott IMx Glycated Hemoglobin assay apparently caused by a high number of leukocytes in patients with chronic lymphocytic leukemia. Because chronic lymphocytic leukemia and diabetes mellitus (monitored by glycohemoglobin measurements) occur more frequently in the elderly, we examined this interference further. The IMx Glycated Hemoglobin assay (...
متن کاملStandardization of glycohemoglobin determinations in the clinical laboratory: three years of experience.
Measurement of glycohemoglobin has been recommended for the long-term assessment of glycemic control in diabetic patients. Because different analytical methods measure different glycohemoglobin species, it has been difficult to compare results between laboratories. Here we report 3 years of experience with calibration of an affinity chromatography method for measuring total glycohemoglobin (GHb...
متن کاملThree assays for glycohemoglobin compared.
Using 123 specimens, we compared the concordance of three different methods for determining glycohemoglobin (GHb): the Diamat (Bio-Rad Laboratories), an automated analyzer measuring HbA1c by cation-exchange chromatography; an assay with the IMx analyzer (Abbott Laboratories), based on boronate affinity binding; and an HPLC method measuring HbA1c by cation-exchange chromatography on a PolyCAT A ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 44 6 Pt 1 شماره
صفحات -
تاریخ انتشار 1998