Incidence Proportion of Acute Cor Pulmonale in Patients with Acute Respiratory Distress Syndrome Subjected to Lung Protective Ventilation: A Systematic Review and Meta-analysis

نویسندگان

  • Saurabh Kumar Das
  • Nang Sujali Choupoo
  • Priyam Saikia
  • Amitabh Lahkar
چکیده

INTRODUCTION Reported incidence of acute cor pulmonale (ACP) in patients with acute respiratory distress syndrome (ARDS) varies from 10% to 84%, despite being subjected to lung protective ventilation according to the current guidelines. The objective of this review is to find pooled cumulative incidence of ACP in patients with ARDS undergoing lung protective ventilation. MATERIALS AND METHODS We searched MEDLINE, EMBASE, Cochrane Library, KoreaMed, LILACS, and WHO Clinical Trial Registry. Cross-sectional or cohort studies were included if they reported or provided data that could be used to calculate the incidence proportion of ACP. Inverse variance heterogeneity (IVhet) and random effect model were used for the main outcome and measures. RESULTS We included 16 studies encompassing 1661 patients. The cumulative incidence of ACP using IVhet analysis was 23% (95% confidence interval [CI] = 18%-28%) over 3 days of lung protective ventilation. Random effect analysis of 7 studies (1250 patients) revealed pooled odd ratio of mortality of 1.16 (95% CI = 0.80-1.67, P = 0.44) due to ACP. CONCLUSION Patients with ARDS have a 23% risk of developing ACP with lung protective ventilation. Findings of this review indicate the need of updating existing guidelines for ventilating ARDS patients to incorporate right ventricle protective strategy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Acute respiratory distress syndrome, mechanical ventilation and right ventricular function].

Mechanical ventilation in acute respiratory distress syndrome (ARDS) implies an increase in alveolar and transpulmonary pressure, giving rise to major alterations in pulmonary circulation and causing right ventricular functional overload that can lead to ventricular failure and thus to acute cor pulmonale. The condition is echocardiographically characterized by dilatation of the right ventricle...

متن کامل

Rationale and Description of Right Ventricle-Protective Ventilation in ARDS.

Pulmonary vascular dysfunction is associated with ARDS and leads to increased right-ventricular afterload and eventually right-ventricular failure, also called acute cor pulmonale. Interest in acute cor pulmonale and its negative impact on outcome in patients with ARDS has grown in recent years. Right-ventricular function in these patients should be closely monitored, and this is helped by the ...

متن کامل

High-frequency ventilation does not provide mortality benefit in comparison with conventional lung-protective ventilation in acute respiratory distress syndrome: a meta-analysis of the randomized controlled trials.

BACKGROUND Despite implementation of lung-protective ventilation strategy, acute respiratory distress syndrome is associated with significant mortality, which necessitates the evaluation of ventilatory modes other than conventional lung-protective strategy. This meta-analysis of the randomized controlled trials has been undertaken to know whether high-frequency oscillatory ventilation (HFOV) pr...

متن کامل

Fluid optimization guided by oesophageal Doppler significantly improves bowel perfusion.

physiology, 8th edn. Philadelphia: Lippincott Williams & Wilkins, 2008: 46–7 3 Vieillard-Baron A, Schmitt JM, Augarde R, et al. Acute cor pulmonale in acute respiratory distress syndrome submitted to protective ventilation: incidence, clinical implications, and prognosis. Crit Care Med 2001; 29: 1551–5 4 Schmitt JM, Vieillard-Baron A, Augarde R, Prin S, Page B, Jardin F. Positive end-expiratory...

متن کامل

Serum levels of N–terminal proB–type natriuretic peptide in mechanically ventilated critically ill patients – relation to tidal volume size and development of acute respiratory distress syndrome

BACKGROUND Serum levels of N-terminal proB-type natriuretic peptide (NT-proBNP) are elevated in patients acute respiratory distress syndrome (ARDS). Recent studies showed a lower incidence of acute cor pulmonale in ARDS patients ventilated with lower tidal volumes. Consequently, serum levels of NT-proBNP may be lower in these patients. We investigated the relation between serum levels of NT-pro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 21  شماره 

صفحات  -

تاریخ انتشار 2017