MR Safety of Implants: Numerical assessment of SAR distribution at design-simplified stents of different lengths placed inside a virtual phantom model investigated at an MR frequency of 63.9 MHz
نویسندگان
چکیده
In respect of imaging quality and patient safety, temperature rises and SAR distributions, which are caused by interaction of the applied electromagnetic fields during MR exams, are of high interest for implants in MR tomography [1]. High local SAR values are equivalent to high local temperature increases [2]. For developing support for radio frequency (RF) induced heating experiments, SAR values were virtually investigated at design-simplified stents with different lengths inside a virtual human torso shaped phantom model
منابع مشابه
Design, Construction and Evaluation of an Anthropomorphic Head Phantom for Assessment of Image Distortion in Stereotactic Radiosurgery Planning Systems
Introduction: In recent years, the use of magnetic resonance (MR) images in radiation treatment planning has drawn considerable attention. However, although the extent of a tumor can be determined in great detail on MR images, the geometric accuracy of these images is limited by distortions stemming from the inhomogeneity of the static background magnetic field, the nonlineari...
متن کاملDesign and Evaluation of a Hybrid Radiofrequency Applicator for Magnetic Resonance Imaging and RF Induced Hyperthermia: Electromagnetic Field Simulations up to 14.0 Tesla and Proof-of-Concept at 7.0 Tesla
This work demonstrates the feasibility of a hybrid radiofrequency (RF) applicator that supports magnetic resonance (MR) imaging and MR controlled targeted RF heating at ultrahigh magnetic fields (B0≥7.0T). For this purpose a virtual and an experimental configuration of an 8-channel transmit/receive (TX/RX) hybrid RF applicator was designed. For TX/RX bow tie antenna electric dipoles were employ...
متن کاملEffects of Mathematical Model of MR Damper on Its Control Performance; A Nonlinear Comparative Study
In this paper, the effect of mathematical representation method of an MR damper on the performance of control algorithm is investigated. The most exact and common Maxwel Nonlinear Slider (MNS) and modified Bouc-Wen hysteretic models are employed through a nonlinear comparatve numerical study. In many of semi-active control algorithms, a mathematical modelling method is required for determinig ...
متن کاملA Transmission Line Matrix Model for Shielding Effects in Stents
In an attempt to determine the RF shielding artifacts produced by conducting stents during MRI scanning of patients, a Transmission Line Matrix (TLM) model was developed based on the symmetrical condensed node. This approach allows considerable flexibility including freedom from stability issues and the ability to reconstruct digital signals in the time or frequency domain. To validate the resu...
متن کاملNumerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator
Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...
متن کامل