Dosimetric review of cardiac implantable electronic device patients receiving radiotherapy

نویسندگان

  • Joann I. Prisciandaro
  • Akash Makkar
  • Colleen J. Fox
  • James A. Hayman
  • Laura Horwood
  • Frank Pelosi
  • Jean M. Moran
چکیده

A formal communication process was established and evaluated for the management of patients with cardiac implantable electronic devices (CIEDs) receiving radiation therapy (RT). Methods to estimate dose to the CIED were evaluated for their appropriateness in the management of these patients. A retrospective, institutional review board (IRB) approved study of 69 patients with CIEDs treated with RT between 2005 and 2011 was performed. The treatment sites, techniques, and the estimated doses to the CIEDs were analyzed and compared to estimates from published peripheral dose (PD) data and three treatment planning systems(TPSs) - UMPlan, Eclipse's AAA and Acuros algorithms. When measurements were indicated, radiation doses to the CIEDs ranged from 0.01-5.06 Gy. Total peripheral dose estimates based on publications differed from TLD measurements by an average of 0.94 Gy (0.05-4.49 Gy) and 0.51 Gy (0-2.74 Gy) for CIEDs within 2.5 cm and between 2.5 and 10 cm of the treatment field edge, respectively. Total peripheral dose estimates based on three TPSs differed from measurements by an average of 0.69 Gy (0.02-3.72 Gy) for CIEDs within 2.5 cm of the field edge. Of the 69 patients evaluated in this study, only two with defibrillators experienced a partial reset of their device during treatment. Based on this study, few CIED-related events were observed during RT. The only noted correlation with treatment parameters for these two events was beam energy, as both patients were treated with high-energy photon beams (16 MV). Differences in estimated and measured CIED doses were observed when using published PD data and TPS calculations. As such, we continue to follow conservative guidelines and measure CIED doses when the device is within 10 cm of the field or the estimated dose is greater than 2 Gy for pacemakers or 1 Gy for defibrillators.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating the effects of esophageal and breast cancer radiotherapy on the cardiac function and determining the relationship between the dosimetric parameters and ejection fraction changes

Background: In the radiotherapy of patients with esophagus and breast cancer, the heart receives a significant dose of radiation that might cause heart complications. Thefore, the aim of the current study was to evaluate the effects of esophagus and left breast cancer radiotherapy on the cardiac function and to determine the relationship between the dosimetric parameters and ejection fraction (...

متن کامل

A national audit of current cardiac device policies from radiotherapy centres across the UK.

AIMS The number of patients with cardiac implantable electronic devices (permanent pacemakers and implantable cardioverter defibrillators) undergoing radiotherapy treatment is increasing. The aims of this audit were to establish current UK practice regarding the management of patients with implanted cardiac devices undergoing radiotherapy and to compare this practice with current 'gold standard...

متن کامل

Effect of Pre-treatment Education Programs on the Anxiety of Patients Receiving Radiotherapy: An Integrative Literature Review

Background: Stress and anxiety in cancer patients are caused by disease diagnosis, unfamiliar experiences, and therapy-related problems. In addition to the short duration of radiotherapy, receiving and understanding of the information about this treatment could be difficult for patients due to anxiety, fatigue, and mental pressure. Training of cancer patients about radiotherapy via educational ...

متن کامل

Re: Estimating and reducing dose received by cardiac devices for patients undergoing radiotherapy

To the Editor: I read with great interest the manuscript of Bourgouin et al.,(1) describing methods to estimate and/or measure out-of-field doses to a cardiac implantable electronic device (CIED) for patients that undergo radiotherapy. This is a topic that deserves great attention in today’s radiotherapy practice since a great number of cancer patients who will receive radiation have a pacemake...

متن کامل

Management of radiation oncology patients with a pacemaker or ICD: A new comprehensive practical guideline in The Netherlands

Current clinical guidelines for the management of radiotherapy patients having either a pacemaker or implantable cardioverter defibrillator (both CIEDs: Cardiac Implantable Electronic Devices) do not cover modern radiotherapy techniques and do not take the patient's perspective into account. Available data on the frequency and cause of CIED failure during radiation therapy are limited and do no...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2015