Comparison of surface electromyography and myotonometric measurements during voluntary isometric contractions.
نویسندگان
چکیده
OBJECTIVES Muscle stiffness increases during muscle contraction. The purpose of this study was to determine the strength of the correlation between myotonometric measurements of muscle stiffness and surface electromyography (sEMG) measurements during various levels of voluntary isometric contractions of the biceps brachii muscle. SUBJECTS Eight subjects (four female; four male), with mean age of 30.6 +/- 8.23, volunteered to participate in this study. METHODS Myotonometer and sEMG measurements were taken simultaneously from the right biceps brachii muscle. Data were obtained: (1) at rest, (2) while the subject held a 15 lb (6.8 kg) weight isometrically and, (3) during a maximal voluntary isometric contraction. Myotonometer force-displacement curves (amount of tissue displacement to a given unit of force applied perpendicular to the muscle) were compared with sEMG measurements using Pearson's product-moment correlation coefficients. RESULTS Myotonometer and sEMG measurement correlations ranged from -0.70 to -0.90. The strongest correlations to sEMG were from Myotonometer force measurements between 1.00 and 2.00 kg. CONCLUSIONS Myotonometer and sEMG measurements were highly correlated. Tissue stiffness, as measured by the Myotonometer, appears capable of assessing changes in muscle activation levels.
منابع مشابه
Prediction of maximal surface electromyographically based voluntary contractions of erector spinae muscles from sonographic measurements during isometric contractions.
OBJECTIVES Currently, there are no studies combining electromyography (EMG) and sonography to estimate the absolute and relative strength values of erector spinae (ES) muscles in healthy individuals. The purpose of this study was to establish whether the maximum voluntary contraction (MVC) of the ES during isometric contractions could be predicted from the changes in surface EMG as well as in f...
متن کاملA comparison of surface and fine wire EMG recordings of gluteus medius during selected maximum isometric voluntary contractions of the hip.
Electromyographic (EMG) studies into gluteus medius (GMed) typically involve surface EMG electrodes. Previous comparisons of surface and fine wire electrode recordings in other muscles during high load isometric tasks suggest that recordings between electrodes are comparable when the muscle is contracting at a high intensity, however, surface electrodes record additional activity when the muscl...
متن کاملVastus lateralis surface and single motor unit EMG during shortening, lengthening and isometric contractions corrected for mode dependent strength differences
Knee extensor neuromuscular activity was investigated during isometric (60° knee angle), shortening and lengthening contractions (50-70°, 10° ·s-1) corrected for force-velocity related differences in intrinsic muscle strength. However, during dynamic contractions additional factors such as shortening induced force losses and lengthening induced force gains may affect muscle strength and thereby...
متن کاملLater stages of diabetic neuropathy affect the complexity of the neuromuscular system at the knee during low-level isometric contractions.
INTRODUCTION This study evaluates the complexity of force and surface electromyography (sEMG) during knee extension and flexion at low-level isometric contractions in individuals with different degrees of diabetic peripheral neuropathy (DPN). METHODS Ten control and 38 diabetic participants performed isometric contractions at 10%, 20%, and 30% of maximal voluntary contraction. Knee force and ...
متن کاملMuscle fatigue resistance during stimulated contractions is reduced in young male smokers.
AIM To determine whether muscle function is compromised in healthy smokers in comparison with activity-matched non-smokers. METHODS Nine male smokers (aged 22.2 +/- 2.5 years: mean +/- SD) with a smoking history of 2.5 +/- 3.1 pack years, and ten male control participants (25.4 +/- 2.9 years) matched for physical activity level participated in this study. Knee extensor strength was measured u...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology
دوره 14 6 شماره
صفحات -
تاریخ انتشار 2004