Transient ischemia does not limit subsequent ischemic regional dysfunction in humans: a transesophageal echocardiographic study during minimally invasive coronary artery bypass surgery.
نویسندگان
چکیده
OBJECTIVES This study sought to assess the effects of sequential coronary artery occlusion during minimally invasive coronary artery bypass graft surgery (CABG) on hemodynamic variables and left ventricular systolic function by means of transesophageal echocardiography (TEE). BACKGROUND Clinical and experimental studies suggest a protective effect of ischemic preconditioning in patients with acute coronary syndromes. However, the effect of repetitive myocardial ischemia on myocardial mechanical function in humans is not completely understood. METHODS Seventeen patients with left anterior descending coronary artery (LAD) stenosis > or =70% and normal rest left ventricular systolic function referred for minimally invasive CABG underwent intraoperative TEE for assessment of regional left ventricular wall motion and measurement of hemodynamic variables at baseline (baseline 1), during a 5-min coronary occlusion (occlusion 1), after a 5-min reperfusion period (baseline 2) and a during a second coronary occlusion during bypass anastomosis (occlusion 2). RESULTS Left ventricular wall motion score (LVWMS) increased significantly from baseline (16.0) to occlusion 1 (21.4+/-3.1 [mean +/- SD], p < 0.05) and occlusion 2 (21.8+/-3.1, p < 0.05). No difference in LVWMS was noted between occlusions 1 and 2. Pulmonary artery systolic pressure increased significantly from baseline (25+/-6 mm Hg) to occlusion 1 (32+/-7 mm Hg, p < 0.05) and occlusion 2 (33+/-6 mm Hg, p < 0.05). Pulmonary artery diastolic pressure also increased significantly from baseline (12+/-4 mm Hg) to occlusion 1 (16+/-4 mm Hg, p < 0.05) and occlusion 2 (16+/-4 mm Hg, p < 0.05). No significant differences in pulmonary artery pressures were noted between occlusions 1 and 2. CONCLUSIONS Ischemic dysfunction was precipitated by the 5-min LAD occlusion, as shown by the increase in LVWMS and pulmonary artery pressure. However, a 5-min coronary occlusion and the resulting ischemia do not alter regional left ventricular systolic function during subsequent ischemia in humans.
منابع مشابه
Echocardiographic Evaluation of the Effects of a Single Bolus of Erythropoietin on Reducing Ischemia-Reperfusion Injuries during Coronary Artery Bypass Graft Surgery; A Randomized, Double-Blind, Placebo-Control Study
Background: Erythropoietin (EPO) is known as a regulating hormone for the production of red blood cells, called erythropoiesis. Some studies have shown that EPO exerts some non-hematopoietic protective effects on ischemia-reperfusion injuries in myocytes. Using echocardiography, we evaluated the effect of EPO infusion on reducing ischemia-reperfusion injuries and improvement of the cardiac func...
متن کاملEffects of nitroglycerin on echocardiographic measurements of left ventricular wall thickness and regional myocardial performance during acute coronary ischemia.
The effects of nitroglycerin on regional left ventricular performance, assessed by echocardiographic techniques, were investigated in anesthetized, open-chest dogs during acute myocardial ischemia. During transient occlusion of the left anterior descending coronary artery, there was end-diastolic thinning and marked reduction in systolic thickening in the central ischemic zone. Similar changes ...
متن کاملA lethal tension pneumothorax during minimally invasive coronary artery bypass surgery: Can transesophageal echocardiography pick it?
Minimally invasive cardiac surgery is establishing itself as the standard of care across the world. MICS CABG is currently performed in only a few centers. Hemodynamics disturbances are peculiar during MICS CABG due to space constraints. We report a 70-year-old man who underwent MICS CABG who developed tension pneumothorax during revascularization that was diagnosed in a novel way.
متن کاملIschemia monitoring in off-pump coronary artery bypass surgery using intravascular near-infrared spectroscopy
BACKGROUND In off-pump coronary artery bypass surgery, manipulations on the beating heart can lead to transient interruptions of myocardial oxygen supply, which can generate an accumulation of oxygen-dependent metabolites in coronary venous blood. The objective of this study was to evaluate the reliability of intravascular near-infrared spectroscopy as a monitoring method to detect possible isc...
متن کاملUse of Carbon dioxide versus air blower in on-pump beating-heart coronary artery bypass surgery
Introduction: The use of carbon dioxide blower has been recognized as the standard of care in patients undergoing beating coronary artery bypass grafting (CABG) due to higher solubility and lower risk of embolization. On the other hand, the compressed air blower has gone out of use since air can be easily trapped and is less soluble which can cause coronary embolism. The prese...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 31 5 شماره
صفحات -
تاریخ انتشار 1998