Biomarker reproducibility in exhaled breath condensate collected with different condensers.
نویسندگان
چکیده
Optimal collection and analysis of exhaled breath condensate (EBC) are prerequisites for standardisation and reproducibility of assessments. The present study aimed to assess reproducibility of EBC volume, hydrogen peroxide (H(2)O(2)), 8-isoprostane and cytokine measurements using different condensers, including a newly developed glass condenser. At four points in time, 30 healthy subjects performed sequential EBC collections randomly using the following four condensers: glass, silicone, EcoScreen (Erich Jaeger GmbH, Hoechberg, Germany) and an optimised glass condenser. In small EBC samples, H(2)O(2) was measured by spectrophotometer, 8-isoprostane by enzyme immunoassay, and cytokines by multiplexed xMAP technology (Luminex Corporation, Austin, TX, USA). The optimised glass condenser yielded significantly more EBC volume (median 2,025 microL, interquartile range 1,600-2,525). The reproducibility of EBC volume, yielded by the new glass condenser, was comparable with EcoScreen (19-20 coefficients of variation (CV)%), but was significantly better compared with silicone and glass (29-37 CV%). The new condenser was associated with significantly more detections of H(2)O(2), 8-isoprostane, interleukin-2, -4, -5 and -13, and tumour necrosis factor-alpha. Isoprostane concentrations were significantly higher using the new condenser, whereas H(2)O(2) and cytokine concentrations were not. Reproducibility of biomarkers was equally variable for all condenser types. In conclusion, significantly more exhaled breath condensate volume and biomarker detections were found using the optimised glass condenser, including higher 8-isoprostane levels. However, biomarker reproducibility in exhaled breath condensate in healthy adults was not influenced by the type of condenser.
منابع مشابه
سنجش نشانگر زیستی IL-6در هوای بازدمی با استفاده از دستگاه جمعآورنده میعانات بازدمی
Background and Objective: The collection of exhaled breath condensate (EBC) is a noninvasive, safe and simple technique to obtain direct samples from lung and use for estimation of the effects of air pollution on human subjects. EBC contains several compounds including simple ions, hydrogen peroxide, proteins, cytokines, deoxyribonucleic acid (DNA), creatine, Electrolytes, trace elements and to...
متن کاملMetabolomic signatures in nuclear magnetic resonance spectra of exhaled breath condensate identify asthma.
By using an Anacon condenser (Biostec, Valencia, Spain), different results have been reported [7]. Collection devices are an important source of variability of EBC biomarkers [2, 3, 8]. The principal variability factors include cooling temperature [9] and condenser materials [2]. For example, a warm-up during condensation is observed when RTube or Anacon are used (condensers using a disposable ...
متن کاملInfluence of condensation temperature on selected exhaled breath parameters
BACKGROUND The effects of changes in cooling temperature on biomarker levels in exhaled breath condensate have been little investigated. The aim of the study was to test the effect of condensation temperature on the parameters of exhaled breath condensate and the levels of selected biomarkers. METHODS Exhaled breath condensate was collected from 24 healthy subjects at temperatures of -10, -5,...
متن کاملBreath condenser coatings affect measurement of biomarkers in exhaled breath condensate.
Exhaled breath condensate collection is not yet standardised and biomarker measurements are often close to lower detection limits. In the current study, it was hypothesised that adhesive properties of different condenser coatings interfere with measurements of eicosanoids and proteins in breath condensate. In vitro, condensate was derived from a collection model using two test solutions (8-isop...
متن کاملReproducibility of exhaled breath condensate pH in chronic obstructive pulmonary disease.
Increasingly, exhaled breath condensate (EBC) is being used to sample airway fluid from the lower respiratory tract. EBC pH may be a biomarker of airway inflammation in chronic obstructive pulmonary disease (COPD). In this study, the reproducibility of EBC pH in COPD was investigated. A total of 36 COPD patients and 12 healthy nonsmoking subjects participated in several investigations: duration...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 31 5 شماره
صفحات -
تاریخ انتشار 2008