We propose a finite-element method (FEM) deformable breast model that does not require elastic breast data for nonrigid PET/MRI breast image registration. The model is applicable only if the stress conditions in the imaged breast are virtually the same in PET and MRI. Under these conditions, the observed intermodality displacements are solely due the imaging/reconstruction process. Similar stress conditions are assured by use of an MRI breast-antenna replica for breast support during PET, and use of the same positioning. The tetrahedral volume and triangular surface elements are used to construct the FEM mesh from the MRI image. Our model requires a number of fiducial skin markers (FSM) visible in PET and MRI. The displacement vectors of FSMs are measured followed by the dense displacement field estimation by first distributing the displacement, vectors linearly over the breast surface and then distributing them throughout the volume. Finally, the floating MRI image is warped to a fixed PET image, by using an appropriate shape function in the interpolation from mesh nodes to voxels. We tested our model on an elastic breast phantom with simulated internal lesions and on a small number of patients imaged, with FMS using PET and MRI. Using simulated lesions (in phantom) and real lesions (in patients) visible in both PET and MRI, we established that the target registration error (TRE) is below two pet voxels.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Finite-element method for intermodality nonrigid breast registration using external skin markers

We are developing a method using nonrigid co-registration of PET and MR breast images as a way to improve diagnostic specificity in difficult-to-interpret mammograms, and ultimately to avoid biopsy. A deformable breast model based on a finite-element method (FEM) has been employed. The FEM “loads” are taken as the observed intermodality displacements of several fiducial skin markers placed on t...

متن کامل

Iterative Deformable FEM Model for Nonrigid PET/MRI Breast Image Coregistration

We implemented an iterative nonrigid registration algorithm to accurately combine functional (PET) and anatomical (MRI) images in 3D. Our method relies on a Finite Element Method (FEM) and a set of fiducial skin markers (FSM) placed on breast surface. The method is applicable if the stress conditions in the imaged breast are virtually the same in PET and MRI. In the first phase, the displacemen...

متن کامل

Localization of Fiducial Skin Markers in MR Images using XXX for PET/MRI Nonrigid Breast Image Registration

In most instances, multiple-modality visualization of pathologies will present advantages over single-modality studies. For many medical imaging procedures, it is desirable to produce a “fused” output that simultaneously exhibits characteristics of the data from each individual modality to reduce the difficulty of the decision-making process for radiologists. Preprocessing for most data fusion ...

متن کامل

Deformable model for 3D intramodal nonrigid breast image registration with fiducial skin markers

We implemented a new approach to intramodal non-rigid 3D breast image registration. Our method uses fiducial skin markers (FSM) placed on the breast surface. After determining the displacements of FSM, finite element method (FEM) is used to distribute the markers’ displacements linearly over the entire breast volume using the analogy between the orthogonal components of the displacement field a...

متن کامل

Roger P . Woods , John C . Mazziotta , and Simon R . Cherry MRI - PET Registration with Automated Algorithm

Objective: We have previously reported an automated method for withinmodality (e.g., PET-te-PET) image alignment. We now describe modifications to this method that allow for cross-modality registration of MRI and PET brain images obtained from a single subject. Methods: This method does not require fiducial markers and the user is not required to identify common structures on the two image sets...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics

دوره 21 Suppl 1  شماره 

صفحات  -

تاریخ انتشار 2006