Retrospective evaluation of patch testing before or after metal device implantation.
نویسندگان
چکیده
OBJECTIVE To review the results of patch testing before or after metal device implantation. DESIGN Retrospective medical chart review. SETTING Tertiary care academic medical center. PATIENTS All patients who underwent patch testing before or after metal device implantation. INTERVENTIONS Patch testing. RESULTS From January 1999 through March 2006, 44 patients underwent patch testing in conjunction with metal device implantation, 22 preoperatively and 22 postoperatively. The reason for preoperative patch testing was a history of allergy to metals. Five patients had positive results for a component of the proposed device. The reasons for postoperative patch testing were unexplained skin eruptions at the implantation site (13 patients), chronic joint pain (8 patients), and joint loosening (1 patient). None of the patients had positive patch test results to a component of the previously implanted device. CONCLUSIONS Although the numbers of patients in this study were small, patch testing performed before metal device implantation was helpful in guiding the choice of device selected. Patch testing after implantation was of limited value.
منابع مشابه
The effect of patch testing on surgical practices and outcomes in orthopedic patients with metal implants.
OBJECTIVE To determine the effect of patch testing on surgical decision making and outcomes in patients evaluated for suspected metal hypersensitivity related to implants in bones or joints. DESIGN Medical chart review. SETTING Tertiary care academic medical center. PARTICIPANTS All patients who had patch testing for allergic contact dermatitis related to orthopedic implants. INTERVENTI...
متن کاملMetal Hypersensitivity Reactions to Orthopedic Implants
Total hip and knee replacement surgery using metal alloy devices is common. Type IV allergic reactions to these implants occur, though infrequently. While uncommon, peri-implant metal allergic reactions may cause significant morbidity for the affected individual-including aseptic loosening, pseudotumor formation and frank device failure. It is challenging to predict who will have these reaction...
متن کاملImplantable cardioverter-defibrillator in a patient with dextrocardia situs inversus
Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...
متن کاملEvaluation of hand Eczema patients by performing Patch test
Background: Various environmental factors can induce or exaggerate hand eczema. Objective: Evaluation of patch test results in hand eczema patients. Patients and Methods: In this descriptive study 100 patients with hand eczema referred to Loghman Hakim and Booali Hospital in Tehran underwent patch testing with 23 allergens obtained from Hermal company. Results: 240 positive reactions observed i...
متن کاملSystematic review and meta-analysis of diagnostic value of epicutaneous patch testing in patients with oral lichenoid lesions
BACKGROUND AND AIM: We sought to carry out a systematic review and meta-analysis of the diagnostic value of epicutaneous patch testing in patients with oral lichenoid lesions (OLLs). METHODS: Bibliographic searches were conducted in electronic databases such as PubMed, the Cochrane library, EBSCO, Scopus, Web of knowledge and Google scholar from January 1990 to December 2011. Search terms re...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Archives of dermatology
دوره 144 8 شماره
صفحات -
تاریخ انتشار 2008