Wear of double crown systems - electroplated vs. casted female part

نویسندگان

  • Stefan BAYER
  • Dominik KRAUS
  • Ludger KEILIG
  • Lina GÖLZ
  • Helmut STARK
  • Norbert ENKLING
چکیده

OBJECTIVES The wear of telescopic crowns is a common problem often reducing the patient's satisfaction with the denture and resulting in a renewal of the denture. The study aims to compare the wear behavior of conical crowns using electroplated copings (group E ) with standard telescopic crowns with cast female parts (group C). MATERIAL AND METHODS 10 conical crowns were milled for each group of a cast gold alloy. The specimen of group E had a conicity of 2º. The cast secondary crowns of group C had a 0º design. The electroplated coping was established by direct electroforming. An apparatus accomplishing 10,000 wear cycles performed the wear test. The retentive forces and the correlating distance during insertion and separation were measured. The wear test was separated in a start phase, an initial wear phase and the long term wear period. The retention force value and the force-distance integral of the first 0.33 mm of each cycle were calculated. RESULTS The retentive forces were significantly higher for group E and the integrals were significantly lower for this group except the integral at cycle 10,000. The changes of retention force and integral did not differ significantly between both groups in all phases. The change of the integrals as well as the integral at the particular cycles showed higher interquartile distances for group C. CONCLUSIONS Within the limitations of this study the tested conical crowns showed clinically acceptable retentive properties. The values reached a range comparable to retentive elements tested in recent literature. The values of group C showed higher ranges. The force measured for group E was significantly higher than for group C but the integrals showed an opposite tendency. The results indicate that an exclusive analysis of the force is not sufficient as the integral is not equivalent to the force although it describes the retentive property of the system in a better way than the force over a distance is described. Both systems seem to be suitable for clinical practice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of retention forces with various fabrication methods and materials in double crowns

PURPOSE The purpose of this study was to analyze the retention force changes and wear behaviours of double-crown systems over long-term use. MATERIALS AND METHODS Ten groups, each consisting of six samples, were evaluated. Specifically, casting gold alloy primary crown - casting gold alloy secondary crown (AA), laser sintering primary crown - laser sintering secondary crown (LL), casting Cr a...

متن کامل

A New Method for Electroplating of Crack-Free Chromium Coatings

In this study, different amounts of MoS2 particles and an anionic surfactant were added to the conventional chromium electroplating bath in order to electrodeposite crack-free chromium coatings and the structure, morphology, tribology and corrosion behavior of the deposited coatings were investigated using X-ray diffraction spectroscopy, scanning electron microscopy, pin on disk ...

متن کامل

Clinical Efficacy of Celecoxib with and without Caffeine versus Ibuprofen for Pain Control following Crown Lengthening Surgery

  Objective: Non-steroidal anti-inflammatory drugs (NSAIDs) are the most commonly prescribed pain control medications following periodontal surgery. This study aimed to compare the efficacy of three drug regimens namely celecoxib, celecoxib + caffeine and ibuprofen for pain relief following crown lengthening surgery.   Methods: This randomized, double blind clinical trial was performed on 45 pa...

متن کامل

Comparison of Permanent Mandibular Molar Crown Dimensions between Mongolians and Caucasians

The aims of this study were to compare crown dimensions of mandibular first molars (M1) and second molars (M2) between Mongolians (belonging to the Khalkha-Mogol grouping) and Caucasians (Northern European ancestry) and to attempt to explain any observed differences in phylogenetic and ontogenetic terms. Materials in this study comprised dental casts of 48 Mongolian female subjects with a mean ...

متن کامل

Wear Resistance of Luting Cements and the Influence of Marginal Gap Width on Substance Loss

Purpose: Scientific data on wear from toothbrushing of luting cements for fixed partial dentures (FPDs) are limited and inconsistent, therefore the study aimed: (1) to investigate the effect of marginal gap width on cement wear and (2) to compare the resistance to wear from toothbrushing of five luting materials in an in vitro model. Materials and Methods: one zinc phosphate cement (ZPC), glass...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 20  شماره 

صفحات  -

تاریخ انتشار 2012